Shop locations

Fluke 353 AC/DC TRMS 2000 A Clamp Meter; Amps Only For Voltage Measurements, See : Fluke 355 Clamp Meters

Fluke Introduces a new line of Clamp meters which promise to surpass expectations, meaning the user can confidently take reliable readings with the true-rms. The Fluke 355/353 Clamp Meters; the tools of choice for high-current measurements up to 2000 A.

The Fluke 353 is designed with extra-wide jaw easily to clamp around large conductors typically found in high-current applications. The rugged design and CAT IV 600 V, CAT III 1000 V ratings, add an extra element of protection when taking high-powered measurements.

Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. The Fluke 353's Sister Clamp meter, the Fluke 355, also measures voltage and resistance, making it one of the most versatile tool for utilities, electrical contractors, and industrial service technicians.
 
Fluke 353 Specifications
Electrical Specifications
Current Measurement DC and AC: 10 Hz to 100 Hz
Range 40A 400A 2000 A; 1400 ac rms
Resolution 10 mA 100 mA 1 A
Accuracy ( A) 1.5% rdg + 15 digits 1.5% rdg + 5 digits
Trigger Level for Inrush 0.50 A 5.0 A 5 A
Trigger Level for Hz Filter Off 2.50 A 2.0 A 8 A
Filter On 0.50 A 2.50 A 8 A
Crest Factor (50/60 Hz)
Range 40A 400A 2000 A; 1400 ac rms
Crest Factor (50/60 Hz) 2 @ 33 A 2 @ 330 A 2 @ 1000 A
2.4 @ 27 A 2.4 @ 270 A 2.4 @ 833 A
Add 2 % to error spec for CF > 2
Current Measurement AC: 100.1 Hz to 1 kHz
Range 40A 400A 2000 A; 1400 ac rms
Resolution 10 mA 100 mA 1 A
Accuracy ( A) 1.5% rdg + 15 digits 1.5% rdg + 5 digits
Trigger Level for Inrush 0.50 A 5.0 A 5 A
Trigger Level for Hz Filter Off 2.50 A 2.0 A 8 A
Filter On 0.50 A 2.50 A 8 A
Frequency measurement
Measurement Range 5.0 Hz to 1 kHz
Resolution 0.1 Hz (15 Hz to 399.9 Hz)
1 Hz (400 Hz to 1 kHz)
Accuracy 5.0 Hz to 100 Hz 0.2 % + 2 counts
100.1 Hz to 1 kHz 0.5 % + 5 counts
Trigger Level Refer to current and voltage tables
Environmental Specifications
Operating Temperature 32 °F to + 122 °F (0 °C to +50 °C)
Storage Temperature -4 °F to 140 °F (-20 °C to +60 °C)
Operating Humidity 0 to 95 % (non-condensing)
Operating Altitude 2000m
Storage Altitude 10,000 m
IP Rating 42 (Indoor use Only)
Drop Test Requirements 1 m
EMI, RFI, EMC FCC part 15, IEC/EN 61326-1:1997 class B
IEC/EN 61326:1997 3V/m, performance criteria B, EN61325
Temperature co-Efficient Current  0.1 % of reading per °C outside 22 °C to 24 °C
Voltage  0.1 % of reading per °C outside 22 °C to 24 °C
General Specifications
Batteries: 6- 1.5 V AA NEDA 15 A or IEC LR6
Test Leads: Rated to 1000 V
Weight: 1.8 lb (.814 kg)
Jaw Size: 2.28 inches (58 mm)
Dimensions (L x W x D): 12 inches x 3.75 inches x
2 inches (300 mm x 98 mm x 52 mm)
Safety Rating: IEC 61010-2-032, 600 V CAT IV.
1000 V CAT III
Ask about this product