Products

Clamp meters

 

 

 
  • Filter
  Name SKU Description Category
TES/PROVA Clamp meters All kinds of Taiwanese Clamp meters. Latest range.   Clamp meters
TEN011-400A-AC/DC Current Transducer   Product Description CAT III 600V AC/DC current ranges 40A and 400A. Maximum conductor size 30mm. Low battery indication. Clamp meters
TEN010-TM-1017V3 400A TRUE-RMS AC POWER CLAMP METER + PHASE ROTATION CAT III 600V Maximum conductor size 30mm. Display counts: 4000. Measures: ACV, DCV, ACA. Measures Phase Sequence. Voltage/Current Harmonics to 25th with THD. W3ø, HV, HA, Phase SEQ, Audible continuity tests. Frequency to 400Hz. Active, Reactive, Apparent power/ energy on. Power Factor, cosø on Single/Three phase systems. Phase sequence. Clamp meters
TEN008-TM-1016V3 AC-HVAC VOLT/AMP/TEMP CLAMP METER WITH TEMPERATURE CAT III 600V 3-3/4 digit LCD Backlit Display, with Analog Bargraph. Display Counts: 4000. Auto Ranging. AC/DC current: 0.1µA to 4000µA. (using test leads). AC current: 0.01A to 400A (using jaw measurement). Ranges: ACV, ACA, DCV, DCA, Resistance, Continuity, Capacitance, and Temperature. Maximum conductor size 30mm. Continuity test below 40 ohms, buzzer will sound. Auto Power off. Double injection outer case. Clamp meters
TEN007-TM-2013V3 TRMS AC/DC CLAMP METER ACA DCA 660A CAT IV 600V, CAT III 1000V LCD backlit display, with maximum reading of 6600. AC voltage range: 0 to 750V. AC current range: 0 to 660A. DC voltage range: 0 to 1000V. DC Current: 0 to 660A. Resistance measurement to 66 megohms. Data Hold, Min/Max, Autoranging, DCA Zero. Test Ranges: ACV, ACA, Resistance, Frequency, Diode, Continuity. Work light. Auto Power Off. Double Injection outer case. Clamp meters
TEN006-TM-1018V3 AC/DC CLAMP METER (CUM AUTOMOTIVE CLAMP) CAT III 600V 3-1/2 digit LCD with Analog Bargraph. Display Counts: 2000. Auto Ranging. Data Hold and Range Hold Auto Zero. Test Ranges: ACV, DCA, ACA, DCV, Resistance, Diode, Continuity. Maximum conductor size 30mm. Continuity test below 25 ohms, buzzer will sound. Auto Power off. Double injection outer case. Clamp meters
TEN005-TM-10124V3 ECONOMICAL AC CLAMP METER ACA400 ACV600 CAT III 600V 3-1/2 digit LCD with Analog Bargraph. Display Counts: 2000. Auto Ranging. Data Hold and Range Hold Auto Zero. Test Ranges: ACV, ACA, DCV, Resistance, Diode, Continuity. Maximum conductor size 30mm. Continuity test below 25 ohms, buzzer will sound. Auto Power off. Double injection outer case. Clamp meters
TEN001-YF-8160 100A LEAKAGE AC CLAMP METER WITH NICKLE STEEL RING DISPLAY: - 3¾ digits LCD with maximum reading 4000. - Overload indication. - Low battery indication. FUNCTIONS: - Peak Hold. - Leakage Current Test. - Test ranges: ACV (600V), ACA (100A) , Ohm, Continuity. - Continuity test below 100Ohm will have buzzer sound. - Alternative for supply frequency. - With LPF (Low Pass Filter) function, 50/60Hz and wide frequency function (40~1KHz).- Maximum conductor size : 30mm.- Dimension : 250mm x 85mm x 35mm. Clamp meters
SEW0063-29404CLV3 SLIM AC CLAMP METER ACV750 DCV1000 ACA1000 ● Pocket size. ● 4000 counts. ● Full automatic measurement.    Voltage measurement.    Current measurement.    Resistor measurement. ● Data hold function. ● Continuity check. ● Diode measurement. ● Select function. ● Low battery indication. ● Auto off function. ● Flashlight (Auto off in 1 minute). Clamp meters
SEW0013 - 2660 CL AC/DC DIGITAL CLAMP METER (AUTO RANGE) 600 ACA/DCA HIGH CAPACITANCE General use AC/DC Clamp meters. Can measure Frequency. Clamp meters
PRO0021-6200V3 Graphic Power Clamp for 1-,3-phase (PF,Harmoncs,KWH) Analysis for Single Phase and Balanced 3 phase system True RMS Value (V and I) Active Power (K,KW,MW,GW) Apparent (VA,KVA,MVA) and Reactive Power (VAR,KVAR,MVAR) Power Factor (PF), Phase Angle( Φ ) Energy (WH,KWH,KVARH,PFH) Programmable PT(1 to 3000)Ratios Display of Overlapped Voltage and Current Waveform Maximum Demand (MD in W,KW,MW) with programmable Period Harmonic Analysis (V and I) to 50th Order Display of 25 Harmonics in one screen Optical Isolated RS-232C... Power clamps
PRO0021-6200 Datalogging Power Clamp Analysis for Single Phase and Balanced 3 phase system True RMS Value (V and I) Active Power (K,KW,MW,GW) Apparent (VA,KVA,MVA) and Reactive Power (VAR,KVAR,MVAR) Power Factor (PF), Phase Angle( Φ ) Energy (WH,KWH,KVARH,PFH) Programmable PT(1 to 3000)Ratios Display of Overlapped Voltage and Current Waveform Maximum Demand (MD in W,KW,MW) with programmable Period Harmonic Analysis (V and I) to 50th Order Display of 25 Harmonics in one screen Optical Isolated RS-232C Interface Smart... Clamp meters
PRO0003-11 AC/DC mA Clamp Meter Max:30A Super High Resolution DC 1mA, AC 0.1mA One Touch Zero for DCA True RMS     Clamp meters
Kyoritsu Clamp meters KYORITSU 2007A DIGITAL AC CLAMP METER KYORITSU 2017 DIGITAL AC CLAMP METER KYORITSU 2002PA DIGITAL 2000A AC CLAMP METER KYORITSU 2002R DIGITAL TRMS AC CLAMP METER KYORITSU 2027 DIGITAL AC TRUE RMS CLAMP METER KYORITSU 2031 DIGITAL CLAMP METER KYORITSU 2412 DIGITAL LEAKAGE CLAMP METER KYORITSU 2413F DIGITAL LEAKAGE CLAMP METER KYORITSU 2417 DIGITAL LEAKAGE CLAMP METER (WP) KYORITSU 2431 DIGITAL LEAKAGE CLAMP METER KYORITSU 2432 DIGITAL LEAKAGE CLAMP METER (HS) KYORITSU 2433 DIGITAL... Clamp meters
Hioki Clamp meters (Malaysia) All range of Hioki clamp from Japan. Clamp meters
HIO0004-Hioki 3282 Frequency Clamp On Hi-Tester (TRMS) From Japan AC Current/Voltage, Frequencies, Resistance, Conduction check, Temperature (probe sold separately) Wave peak value, Waveform distortion check Auto-power off to prevent the power from being left on Non-fuse type protects up to 600 V AC 1000 A AC Ø 46 mm Clamp meters
Fluke Clamp meters All kinds of Fluke Clamp meters. Latest range.   Clamp meters
Chauvin Arnoux/AEMC Clamp meters All kinds of AEMC Clamp meters. Latest range.   Clamp meters
CEN0045A-25-18" FLEXIBLE CURRENT PROBE 3000A (WITHOUT DISPLAY UNIT) Plug into multimeters, oscilloscopes, or power analyzers to measure AC current, up to 3000 A ac. This is also ideal for commercial or residential users who have standard clamp meters, but need to reach hard-to-clamp-on places, or occasionally measure AC current higher than 400 or 600 A. Center 25 simply eases your work. Clamp meters