DKK-TOA AR4/AR5 Series
|
|
Compact 2-electrode type (titanium) detector designed for ultrapure water
Pipeline insertion type, leadless type
Two types of cell constants available: 0.01, 0.1 cm-1
Meas. range
0 - 20/200 MΩ·cm 0 - 0.2/2 μS/cm
|
Industrial Conductivity Detector
|
|
|
DKK-TOA AQM-210A
|
|
Panel Type Resistivity Analyzer AQM-210A
Compact DIN 96 size
Best suited for water quality control in ultra-pure water production lines
Two detectors connectable
RS-232 equipped as standard specification
Output: 2-channel, insulated, 4 - 20mA
Meas. range
0.00 - 20.00 MΩ・cm
|
Panel Type Resistivity Analyzer for Ultra-Pure Water
|
|
|
DKK-TOA AQM-100A
|
|
Resistivity Analyzer for Ultra-Pure Water AQM-100A
Compact DIN 96 size
Best suited for water quality control in ultra-pure water production lines
Two detectors connectable
Meas. range
0.00 - 20.00 MΩ・cm
|
Panel Type Resistivity Analyzer for Ultra-Pure Water
|
|
|
DKK-TOA ALF-1600
|
|
Continuous measurement of alkalinity data in water purification process by coulometric titration method
Requires only 1/4 reagent volume of existing model
RS-485 equipped as standard specification; compatible with Modbus communication system
Freely mountable on walls, racks, etc. for the compact lightweight design
Meas. range
0 - 50/100 mg/L (ppm) (2-ranges)
|
Alkalinity Analyzer
|
|
|
DKK-TOA AF-100
|
|
Enables bacteria and cell measurements in 50 sec.
Highly sensitive measurement at 1 - 1000 cells/mL level
Enables direct measurement of membrane filter
Compliant to sanitary management by swap test
Useful functions such as ATP concentration and cell converted value available
Automatic reagent dispenser is optional (DF-10 sold separately)
|
ATP Analyzer
|
|
|
DKK-TOA ABT-511
|
|
Automatic Burette ABT-511
Precising dispensing system (stable quantitation and speed)
Titration burette (manual titration) supported
GLP compliance
Sampling mode loaded(measure/dilution)
RS-232 equipped as standard specification
|
Automatic Titrator
|
|
|
DKK-TOA AA-1(for Standard) / AA-2 (for Ultrapure Water)
|
|
Single-function (no indication) conductivity analyzer for field installation
Easy installation for the one-unit amplifier and detector
Output: 4 - 20mADC
Power supply: 100VAC
Meas. range
AA-1: 0 - 2 μS/cm to 0 - 10000 μS/cm AA-2: 0 - 0.2/0.5/1.0 μS/cm
|
Conductivity Detectors with Amplifier
|
|
|
DKK-TOA A5/A6 Series
|
|
Hermetically sealed 2-electrode type detector featured with excellent heat-proofing and pressure tightness
Pipeline-insertion/immersion/flow-through/throw-in/leadless, etc. type available
Four types of cell constants available: 0.01, 0.1, 1.0, 10 cm-1
Meas. range
Minimum : 0 - 0.2 μS/cm Maximum : 0 - 20 mS/cm
|
Industrial Conductivity Detector
|
|
|
DKK- TOA CLF-1610
|
|
Measures free residual chlorine of clean water continuously with the reagentless polarographic method
RS-485 equipped as standard specification; compatible with Modbus communication system
Freely mountable on walls, racks, etc. for the compact lightweight design
Meas. range
0 - 1/2, 0 - 1/3, 0 - 2/3 mg/L (ppm) (2-range)
|
Reagentless Free Chlorine Analyzer
|
|
|
DKK- TOA CLD-7M
|
|
Measures chloride demand of water and estimates chlorine injection level; best suited for feed forward control
Meas. range
From 0 - 5 mg/L to 10 mg/L (ppm) From 0 - 10 mg/L to 20 mg/L (ppm)
|
Chloride Demand Analyzer
|
|