DKK-TOA

  • Filter
  Name SKU Description Category
DKK-TOA ME-6/7/11T series (high sensitivity type) Toroidal type teflon detector with excellent corrosion/heat/pressure resistance  Accurate results for high conductivity corrosive solutions (such as strong acid/alkali) Types of detectors available: flow-through, immersion, pipeline insertion, etc. Meas. range Minimum: 0 - 2 mS/cm Maximum: 0 - 2000 mS/cm Electromagnetic Conductivity Detector
DKK-TOA MM-60R 2-Channel model with automatic sensor identification ● Allows for connections of pH/ORP/ion/conductivity/dissolved O2 sensors to either channel ● 0.01/0.001 pH display switchable ● Large color graphic LCD display ● JP16 (The Japanese Pharmacopoeia 16th edition) conformity and stable electric conductivity measurement ● USB (Host) and LAN equipped as standard specification ● External printer connectable ● Multiple samples measurement (turntable connection)... Multi-Function Water Quality Meter
DKK-TOA MM-60R 2-Channel model with automatic sensor identification Allows for connections of pH/ORP/ion/conductivity/dissolved O2 sensors to either channel 0.01/0.001 pH display switchable Large color graphic LCD display JP16 (The Japanese Pharmacopoeia 16th edition) conformity and stable electric conductivity measurement USB (Host) and LAN equipped as standard specification External printer connectable Multiple sample measuring capability (turntable connection) Data storage up to 300... Dissolved Oxygen Meter
DKK-TOA MM-60R Multi-Function Water Quality Meter MM-60R 2-Channel model with automatic sensor identification  Allows for connections of pH/ORP/ion/conductivity/dissolved O2 sensors to either channel  0.01/0.001 pH display switchable  Large color graphic LCD display  JP16 (The Japanese Pharmacopoeia 16th edition) conformity and stable electric conductivity measurement  USB (Host) and LAN equipped as standard specification  External printer connectable  Multiple... pH meters
DKK-TOA MM-60R Multi-Function Water Quality Meter MM-60R  2-Channel model with automatic sensor identification  Allows for connections of pH/ORP/ion/conductivity/dissolved O2 sensors to either channel  0.01/0.001 pH display switchable  Large color graphic LCD display  JP16 (The Japanese Pharmacopoeia 16th edition) conformity and stable electric conductivity measurement  USB (Host) and LAN equipped as standard specification  External printer... Conductivity Meter
DKK-TOA MWB4-70 B4 size compact analyzer excellent in reliability, durability and maintainability Enables continuously measurement of turbidity, color, residual chlorine, pH, conductivity, temperature and pressure without reagents Equipped with interactive easy-to-use color touch panel Automatic Water Quality Analyzer for City Water
DKK-TOA NHMS-4 Simple measurement with just an ion electrode Enables continuous ammonium ion measurements in discharged industrial wastewater, river and water purification plants Automatic cleaning and calibration function ensures stable measurement Easy-to-use touch panel Low-concentration calibration function available Meas. range 0.05 - 5/0.1 - 10/1 - 100 mg/L Ammonium Ion Monitor
DKK-TOA NPW-160 Automated Total Nitrogen/Phosphorus/COD Analyzer NPW-160 Measuring based on official measuring method Multiple-wavelength detector enables measurement of total nitrogen, total phosphorus and COD simultaneously Space-saving design attained by eliminating back piping Drip-proof construction Meas. range Total nitrogen: 0 - 2 mg/L to 50 mg/L Total phosphorus: 0 - 0.5mg/L to 20 mg/L COD (UV method): 0 - 2 Abs Automatic Total Nitrogen/Phosphorus/COD Analyzer
DKK-TOA OBM-100H Panel Type Low-Concentration DO Transmitter OBM-100H Panel type low-concentration DO analyzer in a compact DIN 96 size 2-point regulated, 4 - 20mA, RS-232 output One-touch calibration and various self-diagnostic functions Power supply: 90~264VAC, 50/60Hz Meas. range Minimum : 0 - 20 μg/L Maximum: 0 - 1000 μg/L Transmitter for Industrial Low-Concentration DO Analyzer
DKK-TOA OBM-102A Panel type DO analyzer in a compact DIN 96 size One-touch calibration and various self-diagnostic functions 2-point contacts signal, 4 - 20mA output (RS-232 optional)  Power supply: 90 - 264VAC, 50/60Hz Meas. range Minimum : 0 - 1 mg/L Maximum: 0 - 50 mg/L Panel Type DO Analyzer
DKK-TOA OBM-300 (4-wire) Low-Concentration DO Transmitter OBM-300 (4-wire) Multi-functional low-concentration DO analyzer for field installation in a compact diecast aluminum case 3 ranges (automatically switched), 2-point regulated output Alterable output range One-touch calibration and various self-diagnostic functions Meas. range Minimum : 0 - 20 μg/L Maximum: 0 - 999.9 μg/L Transmitter for Industrial Low-Concentration DO Analyzer
DKK-TOA OC-64 Low-Concentration DO Detector for Pure Water OC-64 Suitable for low-concentration DO measurement (pure water in semiconductor factories, boiler water in power plants) Micro-flow (100mL/min) with special flow cell Electrode: polarograph type 7561L (Ag electrode) or 7563L (Au electrode) Lead wire: ELW-32 Transmitter for Industrial Low-Concentration DO Analyzer
DKK-TOA OC-711 / OC-950 Immersion/Drop-In Type DO Holder OC-711 / OC-950 Lightweight PVC holder; length of immersion type holder: 0.3 - 3.5 m, length of stainless steel protection pipe for drop-in type holder: 2 - 6 m Electrode: polarograph type 7533L (for standard use) or 7536L (for human waste) Immersion/Drop-in Type DO Holder/Detector with Water Jet Cleaner
DKK-TOA ODL-1600 Oil film is detected by measuring differences of the amount of laser reflectance of oil and water With improvements on light source scanning and signal processing, influences occurred in broad water surfaces such as fluctuation, waviness and suspended solids have been reduced effectively Contact-free and easy maintenance  Detectable range 0.3 - 3 m Oil Film Detector
DKK-TOA ODL-1610A Oil Film Detector (Long-Distance Model) ODL-1610A Enables oil film detection even if the surface of sample is 10m away from the detecting cell  Ideal for difficult conditions such as turbulent water and places where is difficult to setup near-water detectors Contact-free and easy maintenance  Detectable range 0.3 - 10 m Oil Film Detector
DKK-TOA ODM-100A (2-wire) / ODM-110A (4-wire) Industrial Low-Concentration DO Transmitter ODM-100A (2-wire) / ODM-110A (4-wire) Easy-to-use low-concentration DO analyzer for field installation in a compact and rigid aluminum case Simplified calibration procedure; auto detection of electrode deterioration Alterable output range Automated self-diagnosis of fault (burn-out output) Meas. range Minimum: 0 - 20 μg/L Maximum: 0 - 2000 μg/L Transmitter for Industrial Low-Concentration DO Analyzer
DKK-TOA OF-1600 Oil film is detected by measuring differences of the amount of LED reflectance of oil and water  Small and lightweight design Contact-free and easy maintenance Detectable range About 0.5 m Oil Film Detector
DKK-TOA OPM-1610 The monitor measures organic pollutant concentration of sample by detecting the absorbance of ultra violet ray(254nm) Stable measurement realized with the UV absorptiomatric method With energy-saving lamp it reduces electricity cost significantly Meas. range Absorbance: 0 - 2.5 Abs Organic Pollution Monitor (UV Instrument)
DKK-TOA OPM-1630 The monitor measures organic pollutant concentration of sample by detecting the absorbance of ultra violet ray (254nm) No cell window and free from fouling for the contact-free measuring method With energy-saving lamp it reduces electricity cost significantly Meas. range Absorbance : 0 - 2.5 Abs Organic Pollution Monitor (UV Instrument)
DKK-TOA OZ-20 / 30 ●Portable, easy calibration, continuous measurement capability ●Two types available: OZ-20(for liquid phase) and OZ-30(for gas phase) ●Easy measurement, simply by placing electrode in the atmosphere ●AC/DC 2-way power source ●Optional flow cell for dissolved ozone Meas. range 1.5 - 19.99mg/L(for liquid), 1 - 100g/m3 (for air) Portable Ozone Meter