• Filter
  Name SKU Description Category
Sew 1807 TB FEATURES ● AC Voltage Input/output range:   100~240 Vac● Frequency:   50~60Hz● Current:   10A     SPECIFICATIONS Current capacity 10Aac(125V) Withstand voltage 2210Vac for 1 minute between the electric circuit and the case ACV Input/Output 100~240V 50/60Hz Dimensions 170(L) x 165(W) x 92(D)mm Weight Approx. 820g Meets EN 61010-1 CAT.Ⅲ... AC & DC Analog Leakage Meters
Sew ST-2600 FEATURES ● Full auto range for V.A and Ω functions.              ● Data hold function freezes the reading in dimly lit or    hard to reach places.        ● Low battery indication.        ● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal     parts. Shielded banana... AC Clamp Meters
Sew ST-3620 FEATURES ● 3½ digit liquid crystal display with maximum reading of 1999.● Over range indication : "1" is displayed on highest digit.● Low battery indication: "B" sign appears on the display.● Response time: approx. 1 second.● Data hold: for all ranges     SPECIFICATIONS               AC A 200 / 1500A ±(2.0%rdg+4dgt) (40Hz-1kHz) AC V 200 / 750V... AC Clamp Meters
Sew ALS-1 FEATURES ● x10 Model allows for more accurate   measurements of low amperage devices.● Direct reading x1 mode.● 4mm Voltmeter input jacks.● Intergrated ground conductor.● 10 amp capacity.     SPECIFICATIONS       Input/Output line connector 3 prong U.S. standard Max. Voltage/Ampere rating 120Vac(±10%)/10Aac Operating Temperature & Relative Humidity 0℃~50℃... AC Line Separators
Sew ALS-2 FEATURES ● x10 Model allows for more accurate   measurements of low amperage devices.● Direct reading x1 mode.● 4mm Voltmeter input jacks.● Intergrated ground conductor.● 10 amp capacity.● 10cm plug cord for greater flexibility.     SPECIFICATIONS         Input plug US / Europe Output socket 3 prong U.S. standard Cord length 10cm Max. Voltage/Ampere... AC Line Separators
Sew HLV-1 FEATURES ● Designed to proof.   AC voltage detectors   AC voltage testers● Compact, handheld, and easy to carry and use.● Battery operated.● LED indicates when power is "ON".● Normal 4mm test leads.     SPECIFICATIONS Output voltage H terminal: AC 400V (± 20%) L terminal: AC 100V (± 20%) Frequency 50-60Hz Power on indicator   ˇ Operating temperature 0°C ~... AC Voltage Proving Units
Sew HLV-2 FEATURES ● Designed to proof.   AC voltage detectors   AC voltage testers● Compact, handheld, and easy to carry and use.● Battery operated.● LED indicates when power is "ON".● Normal 4mm test leads.     SPECIFICATIONS         Output voltage H terminal: AC 690V (±20%) L terminal: AC 100V (±20%) Frequency 50-60Hz Power on indicator   ˇ ... AC Voltage Proving Units
Sew HLV-3 FEATURES ● Designed to proof.   AC voltage detectors   AC voltage testers● Compact, handheld, and easy to carry and use.● Battery operated.● LED indicates when power is "ON".● Normal 4mm test leads.     SPECIFICATIONS         Output voltage H terminal: AC 415V (±20%) L terminal: AC 230V (±20%) Frequency 50-60Hz Power on indicator   ˇ ... AC Voltage Proving Units
Sew 2660 CL FEATURES ● 4000 counts.● Voltage measurement, current measurement, resistor    measurement, frequency counter, capacitor measurement.● Bargraph indication.● Range change function.● Data hold function freezes the reading.● REL function.● Peak function.● VAHz mode measures frequency in ACV and ACA mode.● Diode measurement.● Max / Min function.● Continuity check.● Low battery indication.● Auto Power Off (APO) function.● Safety design... AC/DC Clamp Meters
Sew ST-3600 FEATURES ● 3½ digit LCD with maximum reading of 1999.● Over range indication : "1" is displayed on highest digit.● Low battery indication: "B" sign appears on the display.● Response time: approx. 1 second.● Data hold: for all ranges     SPECIFICATIONS         AC A 200 / 1500A ±(2.0%rdg+4dgt) (40Hz-1kHz) AC V 00 / 750V ±(1.5%rdg+2dgt) (40Hz-1kHz) DC A 200 / 1500A ... AC/DC Clamp Meters
Sew ST-3602 FEATURES ● 3½ digit LCD with maximum reading of 1999.● Over range indication : "1" is displayed on highest digit.● Low battery indication: "B" sign appears on the display.● Response time: approx. 1 second.● Data hold: for all ranges     SPECIFICATIONS         AC A 200 / 1500A ±(2.0%rdg+4dgt) (40Hz-1kHz) AC V 200 / 750V ±(1.5%rdg+2dgt) (40Hz-1kHz) DC A 200 / 1500A ... AC/DC Clamp Meters
Sew 3800 CL FEATURES ● Full auto range for V.A and Ω functions.● Data hold function freezes the reading in dimly lit or hard to reach   places.● Low battery indication.● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded   banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers   and motor coils.    ... AC/DC Clamp Meters
Sew 3801 CL FEATURES ● Full auto range for V.A and Ω functions.● LCD backlight display.● Flashlight function.● Data hold function freezes the reading in dimly lit or hard to reach    places.● Low battery indication.● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded   banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers   and motor... AC/DC Clamp Meters
Sew 3810 CL FEATURES ● Full auto range for V.A and Ω functions.● Data hold function freezes the reading in dimly lit or hard to reach    places.● Low battery indication.● Built-in buzzer for continuity test.● Safety design throughout with no exposed metal parts. Shielded    banana plugs and recessed input terminals.● Ohm function ideal for checking continuity of relays transformers    and motor coils.    ... AC/DC Clamp Meters
Sew 3900 CL FEATURES ● 4000- count LCD.● Full automatic measurement.           ◎ Voltage measurement.           ◎ Current measurement.           ◎ Resistor measurement.           ◎ External frequency measurement.● Range change function.● Data Hold function freezes the reading.●... AC/DC Clamp Meters
Sew 3902 CL FEATURES ● 2000 - count LCD.● Full automatic measurement.          ◎ Voltage measurement.          ◎ Current measurement.          ◎ Resistor measurement.          ◎ Capacitor measurement          ◎ Frequency counter.● Range change function.●... AC/DC Clamp Meters
Sew 3904 CL FEATURES ● 4000 - count LCD.● Full automatic measurement.      ◎ Voltage measurement.      ◎ Current measurement.      ◎ Resistor measurement.      ◎ Capacitor measurement      ◎ Frequency counter.● Range change function.● Data Hold function freezes the reading.● Continuity check.● Diode measurement.● Low battery indication.● Auto... AC/DC Clamp Meters
Sew C5F Series Material: Nylon● Red and black each (set)● Removable cap for attaching alligator clips● Press can be used with all sew 4mm jack test leads● Rating : EN 61010-031:2002 + A1:2008               CAT IV 1000V 0.5A / CAT IV 690V 2A               CAT IV 500V 10A / CAT IV 250V 10A Adapter
Sew AL11-C2 Tip : 2-4 mm● Rating : EN 61010-031:2002 + A1:2008               CAT IV 600V 15A / CAT III 1000V 15A● Red and Black each(set)● Tip : Stainless Steel, sharp tip.● Jack : Nickel Plated, 4mm banana Jack.● The probe tip could screw into crocodile clips.● Probes can be used with all SEW 4mm jack test leads. Adapter
Sew AL11-C4 Tip : 4 mm● Rating : EN/IEC 61010-031:2002 + A1:2008               CAT IV 600V 15A / CAT III 1000V 15A● Red and Black each(set)● Tip : 4mm Stainless Steel caged banana probe tip.● Jack : Nickel Plated, 4mm banana Jack.● The probe tip could be used into non-screw crocodile clips.● Probes can be used with all SEW 4mm jack test leads. Adapter