|
TES-3600 3P4W POWER ANALYZER
|
|
10 Display Easy - to - View LCD Screen.
Connectors for 4 Current Sensing Clamps.
1P2W, 1P3W, 3P3W2M & 3P4W Power Measurement.
True RMS Sensing.
Power KW, KVAR, KVA, PF, θ ,Hz, & Energy KWh, KVARh & KVAh Measurement.
Phase sequency indicator function.
Backlight display function.
Manual Data Memory and Read (99 sets).
Data Logging (504KB Memory, 20,000 sets)
Programmable Trigger - Points and Start / Stop Time.
RS-232 Optical Interface with three phase voltage / current... |
3 Phase Power Analyzer
|
|
|
TES-6830+6801 Power and Harmonics Analyzer (100A) TES-6830+6802 Power and Harmonics Analyzer (1000A) TES-6830+3007 Power and Harmonics Analyzer ( 3000A)
|
|
Analysis for 3P4W, 3P3W, 1P2W, 1P3W
True RMS Value (V 123 and L 123 )
Active Power (W, KW, MW, GW)
Apparent and Reactive Power (KVA, KVAR)
Power Factor (PF), Phase Angle (Φ)
Energy (WH, KWH, KVARH, PFH)
Current Measurement from 0.1mA to 3000A, Capable of Analyzing IT Standby Power Consumption to the Maximum Demand of a Factory
Display of 35 Parameters in One Screen(3P4W)
Programmable CT (1 to 600) and PT (1 to 3000) Ratios
Display of Overlapped Voltage and Current Waveform
2.4M... |
3 Phase Power Analyzer
|
|
|
TES-1340 Hot-Wire Anemometer
|
|
Fast Response Probe.
Air Flow Volume
Instant / Avg / 2/3 Vmax Flow Measurement.
Velocity m/s, ft/min, knots, km/hr, mph.
Data hold & Maximum / Minimum function.
Manual data memory and read function (10 x 99 sets).
LCD triple display.
Auto power off function ON / OFF Time setting.
Backlight function ON / OFF Time setting.
Snake telescoping probe.
|
Anemometer
|
|
|
TES-33 Battery Capacity Tester (USB)
|
|
Test Condition Without Shutting Down Battery.
Simultaneously Measure Battery Resistance, Voltage, Current, Temperature.
Auto-hold and Auto-data storage.
Comparator Function.
Rates Conditions as Pass, Warning, or Fail.
Memory and Read Function
Compact and Lightweight.
USB PC Interface
Storage Battery Systems Battery Capacity Testers, Check battery condition in seconds, with the battery in service!
|
Battery Impedance Tester
|
|
|
TES-32 Battery Capacity Tester (RS-232)
|
|
Test Condition Without Shutting Down Battery.
Simultaneously Measure Battery Resistance, Voltage.
Comparator Function.
Rates Conditions as Pass, Warning, or Fail.
Memory and Read Function
Compact and Lightweight.
RS232 PC Interface
|
Battery Impedance Tester
|
|
|
TES-1356 Sound-Level Calibrator
|
|
94dB and 114dB Sound Calibration at 1KHz
Accurate and Simple to use
Fits 1", 1/2" or 1/4" diameter microphone
|
Calibrator
|
|
|
TES- 1370 NDIR CO 2 METER
|
|
CO 2 : 0 ~ 6,000 ppm range, Diffusion sampling mode.
Three LCD Display for CO 2 , %RH Humidity and Air Temperature.
Maintenance free dual wavelength NDIR infrared CO 2 sensor (non-dispersive infrared).
Continuous or manual data logging (20,000 sets).
Data hold & Maximum / Minimum with Time stamp.
Data Memory and READ function.
Alarm and Time setting.
RS-232 function / Software.
Backlight display function.
Simple and safe to use.
|
CO 2 Tester
|
|
|
TES-135 Color Meter
|
|
Check the color difference between two samples.
Color difference displayed
Δ(L*,a*,b*)
Δ(E*ab,C*ab, H*ab)
Δ(Y, x, y)
Δ(X, Y, Z) or
Δ(Rs, Gs, Bs)
Color space displayed
(L*, a*, b*)
(L*, C*ab, hab)
(Y, x, y)
(X, Y, Z) or
(Rs, Gs, Bs)
Maximum, Minimum and Average function.
Tolerance function.
Auto memory (99 sets) & Read function.
RS232 interface.
|
Color Meter
|
|
|
TES-3010/3012 Prof. Clamp Meter
|
|
ACA: 20A, 200A, 600A
Continuity Buzzer
Unit & Sign Display
|
DC/AC Current Clamp Meter
|
|
|
TES-3040 AC Clamp Meter
|
|
EN61010-1 600V INSTALLATION VAT III POLLUTION DEGREE 2
3-3/4 Digital LCD with bar-graph
Auto-power off with Data Hold and MAX/MIN mode
Zero Adjustment/Relative Reading
|
DC/AC Current Clamp Meter
|
|
|
TES-3050 TRMS AC/DC Clamp Meter
|
|
EN61010-1 600V INSTALLATION VAT III POLLUTION DEGREE 2
3-3/4 Digital LCD with bar-graph
Auto-ranging off / Data Hold / Peak Hold / MAX/MIN mode
Zero Adjustment/Relative Reading
|
DC/AC Current Clamp Meter
|
|
|
TES-3074 AC 1000A Clamp Meter
|
|
Capacitance Measurement (400μF).
MAX / MIN / Data Hold.
Phase Rotation Indicator.
Pos Peak Hold & Neg Peak Hold.
1000A AC & 600V AC.
|
DC/AC Current Clamp Meter
|
|
|
TES-3082 True RMS Clamp Meter
|
|
EN61010-1 600V INSTALLATION VAT III POLLUTION DEGREE2
Auto-Ranging Frequency measurements
Auto ZERO mode
Data Hold mode
PEAK Hold mode
True RMS Reading
|
DC/AC Current Clamp Meter
|
|
|
TES-3091R DC/AC CLAMP METER
|
|
3-1/2 Digital LCD, 2000 count.
Pocket size.
MAX hold / Data hold function.
|
DC/AC Current Clamp Meter
|
|
|
TES-3092 DC/AC CLAMP METER
|
|
3-1/2 Digital LCD, 2000 count.
Pocket size.
MAX hold / Data hold function.
One touch DCA zero.
|
DC/AC Current Clamp Meter
|
|
|
TES-1700 Digital Earth Tester
|
|
Capable of measuring earth voltage.
Data hold , MAX / MIN function.
Auto power off function: The timer operates automatically about 3 minutes when the " Test Button Switch " are pressed to keep the tester power on.
2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test.
In addition to the facility for precision measurement, test leads for simplified two wire measuring system also supplied as standard... |
Earth / Ground Tester
|
|
|
TES-1605 Digital Earth Tester
|
|
Capable of measuring earth voltage.
Data hold function.
Auto power off function: The timer operates automatically about 3 minutes when the " Test Button Switch " are pressed to keep the tester power on.
2mA measuring current permits earth resistance tests without tripping earth leakage current breakers in the circuit under test.
In addition to the facility for precision measurement, test leads for simplified two wire measuring system also supplied as standard accessories.
Automatic... |
Earth / Ground Tester
|
|
|
TES-593 ElectroSmog Meter
|
|
Frequency range 10MHz to 8.0GHz
3 axis isotropic measurements of EMF
Non-directional (isotropic) measurement with three-channel measurement probe
High dynamic range
Configurable alarm threshold and memory function
Easy & safety to use
High frequency (RF) electromagnetic wave field strength measurement
Mobile phone base station antenna radiation power density measurement
Wireless communication applications (CW, TDMA, GSM, DECT)
RF power measurement for... |
EMF Tester
|
|
|
TES-92 ElectroSmog Meter
|
|
50 MHz to 3.5 GHz frequency range.
For isotropic measurements of electromagnetic fields.
Non-directional (isotropic ) measurement with three-channel measurement probe.
High dynamic range due to three-channel digital results processing.
Configurable alarm threshold and memory function.
Easy to use
High frequency (RF) electromagnetic wave field strength measurement.
Mobil phone base station antenna radiation power density measurement.
Wireless communication applications (CW , TDMA ,... |
EMF Tester
|
|
|
TES-1390/1391/1392 EMF TesterElectroMagnetic Field Tester
|
|
The EMF tester is designed to provide user a quick, reliable and easy way to measure electromagnetic field radiation levels around power lines, home appliances and industrial devices.
The EMF tester is a cost effective, hand-held instrument designed and calibrated to measure electromagnetic field radiation at different bandwidths.
Display micro Tesla & milli Gauss in the same tester.
Data hold, Peak hold function
On-line computer (1391/1392) Data logging (1392) function.
|
EMF Tester
|
|