TES-1315/1316 K.J.E.T.R.S.N. Data-Logger Thermometer
|
|
Highly accurate thermometer with thermocouple K, J, E, T, R, S, N type.
Dual input function T1/T2 temperature display. (1316)
7500 DataLogging capacity.
Warning beeper with HI/LO setting.
MAX/MIN with TIME, MAX-MIN AVG, HOLD function.
℃ / ℉ / K User-Selective.
Back-Light LCD display.
|
Thermometer/Infrared Thermometer
|
|
|
TES-1317/1318 Platinum RTD Thermometer
|
|
Pt 3916/3926/385 RTD standard.
7500 DataLogging capacity. (1317)
Warning beeper with HI/LO setting.
Time setting.
MAX / MIN with TIME, MAX-MIN AVG Hold function.
℃ / ℉ / K User-Selective.
Back - Light LCD display.
Dual input function T1/T2 temperature display. (1318)
|
Thermometer/Infrared Thermometer
|
|
|
TES-1319 Thermometer
|
|
Type "K" Thermocouple Input.
Switchable Resolution 0.1° / 1 ° .
With ℃& ℉ switching.
Max / MIN Function.
Data Hold Function.
Flip-up stand.
|
Thermometer/Infrared Thermometer
|
|
|
TES-1326S/1327/1327K Infrared Thermometer
|
|
0.1 ℃/0.2 ℉ Resolution
-35 ℃ ~ 500℃ (-31 ℉ ~ 932 ℉ )
Built-in Laser Targeting / Backlight LCD display
MAX / MIN function
Data memory and read function
Dual thermometer and Dual display (1327K)
Audible and visible alarm (1327/1327K)
Emissivity adjustable (1327/1327K)
|
Thermometer/Infrared Thermometer
|
|
|
TES-1358C Sound Analyzer Real Time 1/1 & 1/3 Octave band Analysis
|
|
Superb high – contrast backlit TFT – LCD color display
Real-time 1/1-Octave and 1/3-Octave analysis
4GB microSD Memory Card
Data transfer using USB
Real time clock with calendar
AC and DC outputs
|
Sound Level Meter
|
|
|
TES-1350A Sound Level Meter
|
|
0.1dB Resolution
Maximum hold function
AUX OUTPUT JACKS
|
Sound Level Meter
|
|
|
TES-1351B Sound Level Meter
|
|
0.1dB Resolution
Maximum hold function
AUX OUTPUT JACKS
|
Sound Level Meter
|
|
|
TES-1352H Programmable Sound Level Meter
|
|
Auto ranging
0.1dB Resolution
Range from 30 to 130dB
A&C Frequency Weighting
Fast/Slow dynamic characteristic
32000 Records Data logging function
USB interface
Real time clock with calendar
|
Sound Level Meter
|
|
|
TES-1353H Integrating Sound Level Meter(RS-232)
|
|
Wide linearity range of 100dB
32000 Records Data logging function
USB interface
Real time clock with calendar
|
Sound Level Meter
|
|
|
TES-1354/1355 Noise Dose Meter
|
|
Measure % Noise Dose / Exposure Time / Sound Level
Real time clock with calendar(1355)
RS-232 interface(1355)
|
Sound Level Meter
|
|
|
TES-1357 Sound Level Meter
|
|
0.1dB Resolution
Range from 30 to 130dB
Fast/Slow dynamic characteristic
A&C Frequency Weighting
|
Sound Level Meter
|
|
|
TES-1358 Sound Analyzer Real Time 1/1 & 1/3 Octave band Analysis
|
|
TES-1358A (230V) TES-1358B (110V)
Real-time 1/1-Octave and 1/3-Octave analysis.
Wide linearity range of 100dB.
Large display with backlighting.
Real time clock with calendar.
Memory max. 10000 records of Lp data.
RS-232 interface.
|
Sound Level Meter
|
|
|
TES-52 Sound Level Meter
|
|
0.1dB Resolution
Range from 30 to 130dB
A&C frequency weighting
Fast/Slow Dynamic characteristic
Maximum with Elapsed time
Manual data memory and read
5Selectable Ranges
Bargraph Indication
Logging Function (99 Sets)
|
Sound Level Meter
|
|
|
TES-3600 3P4W POWER ANALYZER
|
|
10 Display Easy - to - View LCD Screen.
Connectors for 4 Current Sensing Clamps.
1P2W, 1P3W, 3P3W2M & 3P4W Power Measurement.
True RMS Sensing.
Power KW, KVAR, KVA, PF, θ ,Hz, & Energy KWh, KVARh & KVAh Measurement.
Phase sequency indicator function.
Backlight display function.
Manual Data Memory and Read (99 sets).
Data Logging (504KB Memory, 20,000 sets)
Programmable Trigger - Points and Start / Stop Time.
RS-232 Optical Interface with three phase voltage / current... |
3 Phase Power Analyzer
|
|
|
TES-6830+6801 Power and Harmonics Analyzer (100A) TES-6830+6802 Power and Harmonics Analyzer (1000A) TES-6830+3007 Power and Harmonics Analyzer ( 3000A)
|
|
Analysis for 3P4W, 3P3W, 1P2W, 1P3W
True RMS Value (V 123 and L 123 )
Active Power (W, KW, MW, GW)
Apparent and Reactive Power (KVA, KVAR)
Power Factor (PF), Phase Angle (Φ)
Energy (WH, KWH, KVARH, PFH)
Current Measurement from 0.1mA to 3000A, Capable of Analyzing IT Standby Power Consumption to the Maximum Demand of a Factory
Display of 35 Parameters in One Screen(3P4W)
Programmable CT (1 to 600) and PT (1 to 3000) Ratios
Display of Overlapped Voltage and Current Waveform
2.4M... |
3 Phase Power Analyzer
|
|
|
Model 21/23 Power Harmonics and Leakage Tester Model 19 Harmonics and Leakage Tester
|
|
MODEL PROVA 19, 21, 23
True RMS value (V and A)
Leakage Current Measurement at 10 μ A Resolution
Harmonic Analysis (V and A) to the 99 th Order
Better Understanding of High Frequency Harmonic Analysis (up to 5/6 KHz)
Non-interrupted Harmonic Analysis
Analysis of Total Harmonic Distortion (THD-F)
Analysis of Crest Factor (C.F.)
Fast Peak Function (33 μ s and 39 μ s)
Programmable CT Ratio (1 to 250)
Model 21(50A) and 23(100A)
W, KW, H.P.
VA, KVA, VAR, KVAR
PF, Phase Angle (... |
3 Phase Power Analyzer
|
|
|
PROVA-6200 Graphic Power Quality Analyzer
|
|
Analysis for Single Phase and Balanced 3 phase system
True RMS Value (V and I)
Active Power (K,KW,MW,GW)
Apparent (VA,KVA,MVA) and Reactive Power (VAR,KVAR,MVAR)
Power Factor (PF), Phase Angle( Φ )
Energy (WH,KWH,KVARH,PFH)
Programmable PT(1 to 3000)Ratios
Display of Overlapped Voltage and Current Waveform
Maximum Demand (MD in W,KW,MW) with programmable Period
Harmonic Analysis (V and I) to 50th Order
Display of 25 Harmonics in one screen
Optical Isolated RS-232C Interface
Smart... |
3 Phase Power Analyzer
|
|
|
AFLEX-3001/3002 Flexible AC Current Clamp
|
|
True RMS
3000A
Voltage Measurement (AFLEX 3002 only)
Fast Peak Function(30 μs)
MAX/MIN
Auto-Power-Off:30 minutes
Flexible probe, different from normal clamp meter, can pass through obstacles at will and wind many conducting wires simultaneously, max. diameter 170mm |
Flexible AC Current Clamp
|
|
|
AFLEX-3003 Flexible VA Harmonics Tester AFLEX -3005 Flexible Power Quality Tester
|
|
Power Analysis (3005)
W, KW, H.P.
VA ,KVA, VAR, KVAR
PF, Phase Angle( Φ )
Energy (WH, KWH)
Dual displays (W+PF, VA+KVAR)
Balanced 3 Φ Power Quality and Sequence
Harmonics Analysis
True RMS (V and A)
3000 A
Non-interrupted Harmonic Analysis ( V and A ) to the 50th Order in % and Magnitude
Analysis of % THD-F and C.F.
Fast Peak Function (33μs and 39μs)
Programmable PT (1 to 250 )ratios
Auto - Power - Off : 30 Minutes
|
Flexible AC Current Clamp
|
|
|
AFLEX-6300 Graphic Power Quality Analyzer
|
|
Display of Overlapped Voltage and Current Waveform
Maximum Demand (MD in W, KW, MW) with Programmable Period
Harmonics Analysis ( V and I ) to the 50th Order
Display of 25 Harmonics in One Screen with Waveform
Display of waveform with Peak Values (512 Samples / Period), Datalogging of 32, 64, 128 or 256 Points/Cycles
Analysis of Total Harmonics Distortion ( % THD-F )
Graphic Phasor Diagram
Programmable PT (1 to 3000) Ratios
Capture 128 Transient Events ( Time + Cycles + Faults )... |
Flexible AC Current Clamp
|
|