Testo 230-KIT (0563 2305) pH ABS Universal Meter Set
|
|
pH universal set include analysis instrument with 2 electrode clips and battery
Testo buffer set pH 4 and 7, 50 ml each, universal plastic electrode with temperature sensor plastic set case and batteries
Testo 230 combines a complete pH measuring instrument and a high standard thermometer in a compact, waterproof housing
The instrument has automatic temperature compensation and can be calibrated in the pH range with standard and also with DIN buffers
Measures 168 mm length by 72 mm width... |
Water Quality Meters
|
|
|
Testo 230 (0560 2304) Ph and Temperature Meter
|
|
Easy, user-friendly operation
pH/C electrodes are connected via a single plug-in connection
Robust and splashwater-proof (IP 54)
Easy-to-read large 2 line display
Latest probe technology for almost every application
Displays calibration data and error messages
pH and temperature meter in one
Measures 168 mm length by 72 mm width by 27 mm height
Measuring range: 0 to 14 pH
Accuracy: +/-1 digit
+/-0.01 pH (0 to +14 pH)
Resolution: 0.01 pH
Operating temperature: 0 to 40° C
Storage... |
Water Quality Meters
|
|
|
Testo 206-PH3 (0563 2063) Compact pH3 Meter Kit
|
|
External pH probes can be connected
Not affected by dirt particles thanks to the TopSafe protective case
2 line display
Automatic full-scale recognition
1, 2 or 3 point calibration possible
All probes on the market can be connected to the BNC adapter
Testo probes with temperature measurement facilitate temperature compensation
|
Water Quality Meters
|
|
|
Testo 206-PH2-KIT (0563 2066) pH2 Penetration Tip Starter Kit
|
|
Can be used for food containing protein
Combination: pH penetration tip with temperature measurement probe
Automatic full scale value
pH2 probe head for semi-solid food
Leak-proof storage gel
Used for food containing protein
|
Water Quality Meters
|
|
|
Testo 206-PH2 (0563 2062) Ph/Temp Meter w/ pH2 ProbeHead
|
|
Can be used for food containing protein
Combination: pH penetration tip with temperature measurement probe
Automatic full scale value
pH2 probe head for semi-solid food
Leak-proof storage gel
Used for food containing protein
Automatic full-scale recognition
|
Water Quality Meters
|
|
|
Testo 206-PH1-KIT (0563 2065) pH1 Penetration Tip Starter Kit
|
|
Maintenance-free gel electrolyte
Automatic full-scale value recognition
Built-in temperature probe
1, 2 or 3 point calibration possible
TopSafe: Robust, water-tight, hygienic and dishwasher-proof protection case (IP68)
|
Water Quality Meters
|
|
|
Testo 206-PH1 (0563 2061) Ph/Temp Meter w/ pH1 ProbeHead
|
|
Maintenance-free gel electrolyte
Automatic full-scale value recognition
Built-in temperature probe
1, 2 or 3 point calibration possible
TopSafe: Robust, water-tight, hygienic and dishwasher-proof protection case (IP68)
|
Water Quality Meters
|
|
|
Testo 205-KIT (0563 2052) T-Handle pH Meter Starter Kit
|
|
Combined penetration tip with temperature probe
Measuring tip can be changed by user
Maintenance-free gel electrolyte
Backlit display
Audible key feedback
2 line display
Automatic full-scale value recognition
1, 2 or 3 point calibration possible
pH tip embedded in break-proof plastic
Includes on-hand pH/° C measuring instrument with penetration probe, storage cap
Also include gel and calibration bottles (250ml pH 4+7), belt/wall holder and aluminium case
Measuring range: 0 to 14... |
Water Quality Meters
|
|
|
Testo 205 (0563 2051) T-Handle pH Meter
|
|
Combined penetration tip with temperature probe
Measuring tip can be changed by user
Maintenance-free gel electrolyte
Backlit display
Audible key feedback
2 line display
Automatic full-scale value recognition
1, 2 or 3 point calibration possible
pH tip embedded in break-proof plastic
Measurement tip can be replaced by user
0 to 14 pH Range
+/-0.02 pH Accuracy
0.01 pH Resolution
|
Water Quality Meters
|
|
|
Testo 6744 (0555 6744) Dew Point Transmitter with display 1/2 NPT
|
|
Reliable measurement of trace humidity
User-friendly operation with display and control buttons
Calculation of the most important trace humidity variables, also ppm
Protocolled fine adjustment at -40 °C tpd
4 to 20 mA in two-wire technology
Plastic, polyacrylamide housing material
Ambient temperature: -20 to 70 degree C
Storage temperature: -40 to 80 degree C
Protection class: IP 65
Resolution: 12 bit
Accuracy: +/- 40 microA
|
Transmitters
|
|
|
Testo 6743 (0555 6743) Dew Point Transmitter with display G1/2
|
|
Highest reliability
Calculation of the most important trace humidity variables
Adjustment report
Convenient operation
Analog output 4 to 20 mA, 2-wire technology
|
Transmitters
|
|
|
Testo 6742 (0555 6742) Dew Point Transmitter 1/2 NPT
|
|
Highest reliability
Calculation of the most important trace humidity variables
Adjustment report
Convenient operation
Analog output 4 to 20 mA, 2-wire technology
|
Transmitters
|
|
|
Testo 6741 (0555 6741) Plastic Polymer Dewpoint Transmitter G1/2
|
|
Highest reliability
Calculation of the most important trace humidity variables
Adjustment report
Convenient operation
Analog output 4 to 20 mA, 2-wire technology
Ambient temperature: -20 to 70 ° C
Storage temperature: -40 to 80 ° C
Protection class: IP 65
Resolution: 12 bit
Accuracy: +/- 40 microA
Analog output 4 to 20 mA (2-wire technology)
|
Transmitters
|
|
|
Testo 6721 (0555 6721) Plastic Pressure Dewpoint Guard
|
|
Plastic pressure dewpoint guard
Ideal for compressed air cooling driers
Avoid moisture damage by monitoring the cooling drier
Testo humidity sensor (with special trace humidity adjustment) and NTC temperature sensor
Ambient temperature: 0 to 50 ° C
Storage temperature: -40 to 70 ° C
Measurement range/pressure dewpoint: -30 to 30 ° C
Process connection: G1/2 thread
Plastic PAA GF30 housing material
Power supply: 24 VAC/VDC (20 to 30 VAC/VDC max), power consumption 50 mA
|
Transmitters
|
|
|
Testo 6681 (0555 6681) Industrial Humidity Transmitter
|
|
The Highest accuracy up to ±1.0 % RH
First humidity transmitter with Profibus-DP interface
Self-monitoring and early warning guarantee high system availability
Optimum adjustment concept thanks to adjustment of the entire signal chain incl. analog adjustment
P2A software for parameterization, adjustment and analysis saves time and costs in commissioning and maintenance
Calculation and presentation of all relevant humidity parameters
|
Transmitters
|
|
|
Testo 6651 (0555 6651) Humidity Transmitter for Critical Climate
|
|
The Highest accuracy up to ±1.0 % RH
First humidity transmitter with Profibus-DP interface
Self-monitoring and early warning guarantee high system availability
Optimum adjustment concept thanks to adjustment of the entire signal chain incl. analog adjustment
P2A software for parameterization, adjustment and analysis saves time and costs in commissioning and maintenance
|
Transmitters
|
|
|
Testo 6444 (0555 6444) DN50 Compressed Air Flow Transmitter
|
|
Leakage detection, compressed air consumption
meaurement
Consumption cost allocation
Peakload management
Measuring range: 2.3 to 700 Nm³/h
Pipe diameter: DN 50 (for 2" pipes)
Weight: 3.8 kg
Max. display value norm volume flow: 840 Nm³/h
Min./max. monitoring
Control of consumption-dependent maintenance
strategies
Automatic, exact compressed air dosage
|
Transmitters
|
|
|
Testo 6443 (0555 6443) DN40 Compressed Air Flow Transmitter
|
|
Leakage detection, compressed air consumption
meaurement
Consumption cost allocation
Peakload management
Measuring range: 1.3 to 410 Nm³/h
Pipe diameter: DN 40 (for 1 1/2" pipes)
Weight: 3.0 kg
Max. display value norm volume flow: 492 Nm³/h
Min./max. monitoring
Control of consumption-dependent maintenance
strategies
Automatic, exact compressed air dosage
|
Transmitters
|
|
|
Testo 6442 (0555 6442) DN25 Compressed Air Flow Transmitter
|
|
Leakage detection, compressed air consumption
meaurement
Consumption cost allocation
Peakload management
Measuring range: 0.75 to 225 Nm³/h
Pipe diameter: DN 25 (for 1" pipes)
Weight: 1.1 kg
Max. display value norm volume flow: 270 Nm³/h
Min./max. monitoring
Control of consumption-dependent maintenance
strategies
Automatic, exact compressed air dosage
|
Transmitters
|
|
|
Testo 6441 (0555 6441) DN15 Compressed Air Flow Transmitter
|
|
Leakage detection, compressed air consumption
meaurement
Consumption cost allocation
Peakload management
Measuring range: 0.25 to 75 Nm³/h
Pipe diameter: DN 15 (for 1/2" pipes)
Weight: 0.9 kg
Max. display value norm volume flow: 90 Nm³/h
Min./max. monitoring
Control of consumption-dependent maintenance
strategies
Automatic, exact compressed air dosage
|
Transmitters
|
|