Chauvin Arnoux CA 6545 5KV Insulation Tester
|
|
5KV Insulation Tester
THE CA6545 MEGOHMMETER CAN BE USED FOR QUANTITIVE AND QUALITATIVE ANALYSIS OF INSULATION
In a hard casing that is site-adapted for the most severe measuring conditions, the CA6545 offers the very best in insulation testing technology and accuracy.
Chauvin Part No: P01139701
|
HV Insulation Testers
|
|
|
Chauvin Arnoux CA6412 Earth Clamp
|
|
Earth Clamp
EARTH CLAMP FOR STAKELESS EARTH MEASUREMENTS
Each Chauvin clamp-on earth resistance tester is delivered in a carrying case with one 9V battery and a user’s manual.
Chauvin Part No: P01122012
|
CA6412 Earth Clamp
|
|
|
Chauvin C.A6503
|
|
Hand-cranked Insulation Tester
HAND-CRANKED MEGOHMMETER CAN BE USED TOTALLY INDEPENDENTLY BECAUSE IT IS POWERED BY A MAGNETO
100% ready to use - 100% energy consumption!
Chauvin Part No: P01132504
Web Price: Only £421 each
|
Insulation & Continuity Testers
|
|
|
Ex 171-3
|
|
Ex 171-3, humidity data logger %RH, °C, incl. starting magnet, battery and calibration protocol; calibration certificates (ISO/DKD) must be ordered separately
Theft-proof mounting
Control and adjustment option with adjustment set
1-channel: Internal %RH/°C
|
Datalogger
|
|
|
BW Gas Alert Clip Extreme 24 Month Gas Detectors
|
|
The BW GasAlertClipExtreme is portable single gas detector designed for users with fixed-duration projects or those who need a go/no-go monitor that's lightweight, compact and easy-to-use. The GA24XT is entirely maintenance free for 24 months
GasAlertClip Extreme - Waterproof 2-Year Disposable Gas Detector with Event Logging.
Simply press the START/TEST button and the GasAlertClip Extreme is ready to use, providing two years of continuous, maintenance-free operation from the day of... |
Single gas detectors
|
|
|
testo 175 T1 (0572 1751) 1-Channel Temp Logger with Internal NTC Sensor
|
|
Features
One button operation - Click and “GO” button instantly starts logging and recording.
TWO standard interfaces - Mini USB and SD card for easiest direct communication with your PC - no added interface required.
Large display w/ one button backlight - For easily viewing data in poorly lit areas.
Longer battery life - Designed to conserve energy for data recording without interruption. Up to 3 years battery life. Standard battery (AA) replaceable by user.
Larger memory - Collect... |
Datalogger
|
|
|
DKK-TOA HM-30R
|
|
Large color graphic LCD display
0.01/0.001 pH display switchable
High-performance with the Strong&Float (internal solution concentration checker) pH electrode
USB (Host) and LAN equipped
Multiple sample measuring capability (turntable connection)
Meas. range
pH 0.000 - 14.000 0.0 - ±2000.0mV (ORP electrodes sold separately) 0 - 100.0℃ |
pH meters
|
|
|
DKK-TOA HDM-135A(2-wire)/HDM-136A(4-wire)
|
|
Industrial pH Transmitter HDM-135A(2-wire)/HDM-136A(4-wire)
Easy-to-use pH analyzer for field installation in a compact and rigid aluminum enclosure
Easier calibration done with standard solution
Auto determination of electrode deterioration
Alterable output range
Automated self-diagnosis of fault (burn-out output)
Meas. range
-1 - 14
|
Transmitter for Industrial pH/ORP Analyzer
|
|
|
DKK-TOA HM-30P / 31P
|
|
Standard model for pH measurement (HM-30P)
Sophisticated type, capable of pH and ORP measurements (HM-31P)
Power-saving design; rechargeable battery adaptable
Waterproof design (IP67: 1m depth, up to 30mins)
Data storage up to 1000 points
Meas. range
pH 0 - 14 (HM-30P/31P) 0 - 100.0 degrees C (HM-30P/31P) 0 - ±2000 mV (HM-31P) (ORP electrodes sold separately) |
Handheld pH/ORP Meter
|
|
|
DKK-TOA WDM-135A (2-wire) / WDM-136A (4-wire)
|
|
Industrial Conductivity Transmitter WDM-135A (2-wire) / WDM-136A (4-wire)
Easy-to-use conductivity analyzer for field installation in a compact and rigid aluminum enclosure
Wide application range from ultra-pure water to wastewater
Alterable output range
Meas. range
Minimum: 0 - 0.2 μS/cm Maximum: 0 - 20 mS/cm |
Transmitter for Industrial Conductivity Analyzer
|
|
|
DKK-TOA AQM-100A
|
|
Resistivity Analyzer for Ultra-Pure Water AQM-100A
Compact DIN 96 size
Best suited for water quality control in ultra-pure water production lines
Two detectors connectable
Meas. range
0.00 - 20.00 MΩ・cm
|
Panel Type Resistivity Analyzer for Ultra-Pure Water
|
|
|
DKK-TOA MDM-135A (2-wire)
|
|
Electromagnetic Conductivity Transmitter MDM-135A (2-wire)
Electromagnetic conductivity analyzer for field installation in a compact and rigid aluminum enclosure
Made for accurate measurements for high conductivity corrosive solutions (such as strong acid/alkali)
Alterable output range
Meas. range
Minimum : 0 - 2 mS/cm Maximum : 0 - 2000 mS/cm
|
Transmitter for Electromagnetic Conductivity Analyzer
|
|
|
DKK-TOA OBM-102A
|
|
Panel type DO analyzer in a compact DIN 96 size
One-touch calibration and various self-diagnostic functions
2-point contacts signal, 4 - 20mA output (RS-232 optional)
Power supply: 90 - 264VAC, 50/60Hz
Meas. range
Minimum : 0 - 1 mg/L Maximum: 0 - 50 mg/L
|
Panel Type DO Analyzer
|
|
|
DKK-TOA XAT-200 series
|
|
Process analyzer for automating analytical techniques such as atomic absorption and etc.
Suitable for automating chemical analysis processes such as distillation, heat treatment, etc.
Example applications:
*Total chromium *Total cyanide by atomic absorption/distillation *Phenols by atomic absorption/distillation *Total mercury by oxidation-reduction atomic absorption |
Automatic Process Analyzer
|
|
|
DKK-TOA MWB4-70
|
|
B4 size compact analyzer excellent in reliability, durability and maintainability
Enables continuously measurement of turbidity, color, residual chlorine, pH, conductivity, temperature and pressure without reagents
Equipped with interactive easy-to-use color touch panel
|
Automatic Water Quality Analyzer for City Water
|
|
|
DKK-TOA BSC
|
|
A complete sampling system composed with cooler, pressure reducer, valves, flowmeter and thermostat chambers
Enables sampling for analysis from the boiler
Consistent manufacturing from analyzer to sampler
Sample condition
Maximum temperature: 600 degrees C Maximum pressure: 30 MPa Maximum flow rate: 3 L/min
|
Boiler Sampling System
|
|
|
DKK-TOA BPM-2000
|
|
Designed for oil refinery
Automatic fractional distillate analyzer of batch distillation type enables distillation test of petroleum products such as kerosene, diesel oil, gasoline and etc.
Adopts high resolution liquid level detecting sensor
Newly-developed FA computer embedded with large-sized, color touch panel
Explosion-proof TIIS fd2G4 certified
Meas. range
Standard:Light gas oil (0 - 400 degrees C), Kerosene (0 - 300 degrees C), Gasoline (0 - 200degrees C)
|
Boiling Point Analyzer
|
|
|
DKK-TOA NPW-160
|
|
Automated Total Nitrogen/Phosphorus/COD Analyzer NPW-160
Measuring based on official measuring method
Multiple-wavelength detector enables measurement of total nitrogen, total phosphorus and COD simultaneously
Space-saving design attained by eliminating back piping
Drip-proof construction
Meas. range
Total nitrogen: 0 - 2 mg/L to 50 mg/L Total phosphorus: 0 - 0.5mg/L to 20 mg/L COD (UV method): 0 - 2 Abs
|
Automatic Total Nitrogen/Phosphorus/COD Analyzer
|
|
|
DKK-TOA FPM-377
|
|
PM2.5 Monitor FPM-377
Environment Ministry (JAPAN) Approval
Beta ray attenuation method (mass concentration)
Heater type dehumidifier
VSC cyclone (USEPA approval)
Outdoor type and indoor type available
Meas. range
0 - 500, 0 - 1000, 0 - 5000 μg/m3
|
Particulate Monitor
|
|
|
Lutron 50A/50mV SHUNT - ST-50
|
|
|
Adapter Series
|
|