Products

MM-60R Benchtop R SeriesMulti Function Water Quality Meters

Category: Water

Multi Function Water Quality Meters

The new MM-60R Benchtop R Series Meter
with advanced features and exclusive sensor memory

Dual Channels for pH, ORP, Ion, Conductivity, Resistivity, Salinity, Concentration, Dissolved Oxygen, Saturation, and Temperature. (Plus Ambient temp. and humidity)

The MM-60R Benchtop Multi-Function Meter. Simply stated.."Awesome!" 
The new R series meters are designed for high performance with easy operation. The MM-60R combines years of instrument development, exclusive sensor technology, along with unmatched performance to offer a multi-parameter, Multi channel, full function benchtop meter for an entire array of applications. 
Features:

  • The DKK-TOA exclusive calibration memory function. Intelligent Sensor "Calibration Memory" - The electrode stores 3 sets of calibration data in a microchip of the electrode including calibration date, sensor type, ID #, etc.. The information is downloaded to the pH meter when attached. Always a documented electrode with complete paper trail.
  • GLP Compliant- Compatible with electronic recording and electronig signature regulations under 21 CFR Part 11.
  • SOP Documentation guide available.
  • On-board Help function at your fingertips
  • USB and LAN-network interface connectivity
  • Password protection and enhanced printing functions. User restricted access.
  • Calibration data storage function (20 sets of data), including sensor ID, cal data, zero potential and slope. Sensor replacement function and alarm indications. Diagnostic messages are displayed when an error indication is found.
  • Easy to read and use menu driven operation, back lit large LCD display.
  • Up to a 5-point automatic pH calibration with automatic recognition of US standard, JIS Standard, or other buffers.
  • Ambient temperature and humidity logging available.
  • Data storage function- up to 300 sets of measured data can be stored in memory, each channel!.
  • System expandability)- optional peripherals can be added such as turn tables (12,18, or 36 samples) and electrode selector (max 5 electrodes).

Also consider the individual R-series Conductivity Meters and the pH Meters 
The MM-60R Multi-Function Meter


Description: http://www.analyticon.com/analyticon/products/laboratory/images/mm60r.jpg

MM-60R

Main Unit


MM-60R

Multifunction Meter w/Standard Accessories.

Optional equipment and accessories for MM-60R


6949070K (HM-30R, CM-30R, MM-30R)

Ambient Temperature and humidity sensor

6949080K (HM-30R, CM-30R, MM-30R)

Remote switch for auto hold, data memory, and print key

EPS-R

External printer unit w/cable, 60mm wide

118B603

Connection cable to external printer

P000119

60mm wide printer Paper, 20 roll/pk

ORD00001

Ink Ribbon Cartridge for External Printer, 1 pc

G-LOG2

Data Acquisition Software for PC to CSV format. (Requires 118B604 RS-232C cable, 2m)

R-LOG

USB/LAN data collection software for PC to CSV format.

ES-1G (HM-30R, MM-60R)

Electrode Selector for up to 5 pH, ORP, or Ion electrodes

ES-1GC (CM-30R, MM-60R)

Conductivity Cell Selector for up to 5 Cond. Cells

ES-1GC (MM-60R)

Electrode Selector for up to 5 DO electrodes

AH-1G

Automatic Electrode Calibration Unit

AC-1V (HM-30R, CM-30R. MM-60R)

Control Box allows for upper and lower pH limits to be controlled by 100 V relay for reagent pump/pH control..

OGC00002

RS-232 Conection Cable, 2m.

PC-1G (HM-25R, HM-30R, MM-60R)

pH Checker / Calibration unit

EC-1G (CM-25R, CM-30R, MM-60R)

Electrical Conductivity Check test plug.

TC-1G (HM, CM, or MM R-series)

Temperature Checker test plug.

OIF00001

Electrode Stand Set

OIB00001

Electrode Holder (Electrode Attachment Not included)

OIB00004 - OIB00008

Electrode Attachment, G/04, J/05, Ion/06, DP/07, N/08

 

Stirrers assemblies:

ST-15

Magnetic stirrer

S-HLD-S

Electrode Holder

S-STD-S

Electrode Stand

ST-20A

Overhead Rod type stirrer and electrode holder

 

Automatic Samplers:

TTT-510-12

Automatic turntable unit, 12 samples.(uses 200ml tall beakers)

TTT-510-18

Automatic turntable unit, 18 samples.(uses 100ml tall beakers)

TTT-510-32

Automatic turntable unit, 32 samples.(uses 50ml tall beakers)

TTT-510-60

Automatic turntable unit, 60 samples.(uses 20ml tall beakers)

OGC00001

G Series meter to TTT-510 Connection Cable, 1.5M(std)

P000020

Waste Water Valve

P000021

Waste Water Valve, electric magnetic

P000022

Non-Aqueous pump for reagent delivery

P000032

Propeller Stirrer motor

 

Additional electode holders, connection cables, extensions, beakers, and accessories also available.

pH Electrodes


GST-5741C (General Purpose)
(Standard with HM-30R)

Strong pH Glass Electrode, 0-14pH, 0-100C (3 in 1; pH, Ref, Temp.) Min. 1ml sample volume. Calibration Memory function

ELP-031 (Organic Solvent)

Strong pH Glass Electrode, 0-14pH, 0-100C (3 in 1; pH, Ref, Temp.) Moveable sleeve junction. Min. 3ml sample volume. Calibration Memory function

ELP-032 (Precision pH))

Strong pH Glass Electrode, 0-14pH, 0-60C (3 in 1; pH, Ref, Temp.) Fixed sleeve junction. Min. 2ml sample volume. Calibration Memory function

GST-5723S (Precision Trace Volume)

pH Glass Electrode, 0-11pH, 0-60C (3 in 1; pH, Ref, Temp.)
1ml sample volume. Calibration Memory function

GST-5724C (Insertion/spear type, Neutralization)

pH Glass Electrode, 0-12pH, 0-60C (3 in 1; pH, Ref, Temp.)
0.5ml sample volume. Calibration Memory function

ELP-035 (Trace sample volume)

5mm Diam. Strong pH Glass Electrode, 0-13pH, 0-100C (3 in 1; pH, Ref, Temp.) 0.5ml sample volume. Calibration Memory function

ELP-036 (Ultra trace Volume)

3mm Diam. Strong pH Glass Electrode, 0-13pH, 0-60C (3 in 1; pH, Ref, Temp.) 0.3ml sample volume. Calibration Memory function

ELP-037 (Test Tube use)

8mm Diam., long body, Strong pH Glass Electrode, 0-13pH, 0-100C (3 in 1; pH, Ref, Temp.) 0.5ml sample volume. Calibration Memory function

ELP-038 (Ultra trace, narrow test tube use, NMR tube, etc.)

3mm Diam., long body, Strong pH Glass Electrode, 0-13pH, 0-60C (3 in 1; pH, Ref, Temp.) 0.3ml sample volume. Calibration Memory function

GST-5720C (Flow Thru monitoring)

pH Glass Electrode 0-12 pH, 0-60C (3 in 1; pH, Ref, Temp.)
250ul cell volume for continuous monitoring.

ELP-039 (Strong Alkali Use)

pH Glass Electrode, 0-14pH, 0-100C (3 in 1; pH, Ref, Temp.)
1ml sample volume. Calibration Memory function

ELP-040 (Hydrofluoric Acid Use)

pH Glass Electrode, 2-12pH, 0-50C (3 in 1; pH, Ref, Temp.)
30ml sample volume. Plastic body with replaceable glass tip. Calibration Memory function

GST-5731C (General Purpose)
(Standard with HM-25R)

Strong pH Glass Electrode, 0-14pH, 0-100C (3 in 1; pH, Ref, Temp.) Min. 1ml sample volume.

PST-5721C (General Purpose ORP) (Reduction-Oxidation)

ORP Electropde. 0-100C. 3 in 1 ORP Platinum Electrode, (mV, Ref, Temp.) 1ml samlpe volume. Calibration Memory function.

Dissolved Oxygen Electrodes


OE-270AA
Immersion / throw-in use

DO: 0-20mg/L, 0-200% / 0-500% saturation, 0-50C, Electrolyte R-9 (OBG00007), Uses OCC00001 membrane set (High conc. use OCC00002). Cable Length: 3m standard. (5 and 11m available).
Calibration memory function.

OE-570BA
Immersion / throw-in use 
No flow use

DO: 0-20mg/L, 0-200% / 0-500% saturation, 0-50C, Electrolyte R-9 (OBG00007), Uses OCC00023 membrane set (High conc. use OCC00024). Cable Length: 3m standard. (5 and 11m available).
Calibration memory function.

OE-470BA
Egg Bottle or BOD bottle use
suitable for No flow use

DO: 0-20mg/L, 0-200% saturation, 0-50C, Electrolyte R-9 (OBG00007), Uses OCC00022 membrane set. Cable Length: 1m standard. Calibration memory function.

OE-470AA
Egg Bottle or BOD bottle use
Built in stirrer

DO: 0-20mg/L, 0-200% saturation, 0-50C, Electrolyte R-9 (OBG00007), Uses OCC00022 membrane set. Cable Length: 1m standard. Built in stirrer. Calibration memory function.

Conductivity Cells


CT-57101B (General Purpose)
Immersion type

EC: 100uS/m to 10S/m (1uS/cm to 100ms/cm), 0-100C., Cell const. 100E10-1m, Min. 4ml sample volume. Diam 14mmx26mm. Built in temp. Calibration Memory function

CT-57101C (Low Range Cond.)
Immersion type

EC: 5uS/m to 1S/m (0.05uS/cm to 10ms/cm), 0-100C., Cell const. 10E10-1m, Min. 6ml sample volume. Diam 14mmx42mm. Built in temp. Calibration Memory function

CT-57101A (High Range Cond.)
Immersion type

EC: 1mS/m to 100S/m (10uS/cm to 1S/cm), 0-100C., Cell const. 1000E10-1m, Min. 39ml sample volume. Diam 36mmx38mm. Built in temp. Calibration Memory function

CT-87101B (General Purpose)
Flow Thru type

EC: 100uS/m to 10S/m (1uS/cm to 100ms/cm), 0-100C., Cell const. 100E10-1m, Cell volume is 4ml. Built in temp. Calibration Memory function

CT-27111D (Pure Water Use)
Flow Thru type

EC: 5uS/m to 20S/m (0.05uS/cm to 200ms/cm), 0-80C., Cell const. 1E10-1m, Cell volume is 8ml. Built in temp. Calibration Memory function. Note: a seperate flow cell is required. CEF-22A (PP), or CEF-23A (SUS316)

CT-87101C (Low Range Cond.)
Flow Thru type

EC: 5uS/m to 1S/m (0.05uS/cm to 10ms/cm), 0-100C., Cell const. 10E10-1m, Cell volume is15ml. Built in temp. Calibration Memory function

CT-87102A (High Range Cond.)
Flow Thru type

EC: 10mS/m to 100S/m (100uS/cm to 1ms/cm), 0-100C., Cell const. 2000E10-1m, Cell volume is 1ml. Built in temp. Calibration Memory function. Note: a rubber syringe septum or pump tube is required.

Specific Ion Electrodes:


Electrode

Measuring Range

pH range/temp

Influence of co-existent ions (selective coefficient)

Ion Tip replacement

Membrane

Sodium ion, combination
NA-2011

2.3 - 23K mg/l Na+

10-11 pH / 60C

Mg+2, Ca+2, NH4+, Li+, K+=10E3

NA-100B

Glass membrane

Potassium ion, combination
K-2031

0.39 - 39K mg/l k+

5-6 pH / 50C

H+=10E2, NH4+=3x10E2, Na+=2x10E3, Li=10E4

K-300B

Liquid Membrane

Calcium ion, combination
CA-2031

0.4 - 40K mg/l Ca+2

5-6 pH / 50C

Pb+2=33, Zn+2=45, Mn+2=1.7x10E2, Cd+2=8.8x10E2, Fe+2=1.2x10E3, Mg+2=1.8x10E3, Ba+2=1.9x10E3, Cu+2=2.7x10E3, Ni+2=9.0x10E3

CA-300

Liquid Membrane

Fluoride ion, combination 
F-2021

0.019 - 19K mg/l F-

5-6 pH / 50C

OH-=10E1, HPO4-2, HCO3-=10E3(pH7-8), Cl-, Br-, I-, NO3-, SO4-2,S2O3-2=10E5

F-200

Solid Membrane

Chloride ion, combination 
CL-2021

1 - 35K mg/l Cl-

5-6 pH / 50C

S-2 must be absent, CN-, I-=10E5, Br-, S2SO3-2+10E-2, F-,NO3-, SO4-2, CO3-2, PO4-3=10E3

CL-200B

Solid Membrane

Cyanide ion, combination
CN-2021

0.003 - 26 mg/l CN-

12-13 pH / 50C

S-2 must be absent, I-=10E-1, S2O3-2=10E1, Br-=10E3, NO3-, SO4-2, PO4-3=10E4, CO3-2, Cl, F-=10E5(at 10 mol/l)

CN-200B

Solid Membrane

Nitrate ion, combination
N-2031

0.62 -62K mg/l NO3-

5-6 pH / 50C

I-=7x10E-2, Br-=1.7, NO2-=4.5, Cl-=2x10, CH3COO=1.2x10E2, SO4-2, CO3-2=1.7x10E2, F-=2x10E2

N-300

Liquid Membrane

Bromide ion, combination
BR-2021

0.8 - 80K mg/l Br-

5-6 pH / 50C

S-2 must be absent, CN-,I-=10E-4, S2SO3-2, SCN-=10E0, Cl=10E2, NO3-, SO4-2, CO3-2, F-=10E4

BR-200

Solid Membrane

Iodide ion, combination
I-2021

0.01 - 127K mg/l I-

5-6 pH / 50C

S-2 must be absent, CN-=10E0, S2SO3-2=10E1, SCN-=10E3, Br=104, NO3, CO3-2, PO4-3, Cl-, F-=10E5

I-200

Solid Membrane

Cadmium ion, combination
CA-2021

0.01 - 1120 mg/l Cd+2

5-6 pH / 50C

Hg+2, Ag+2, CU+2 must be absent, Pb+2, Fe+3=10E0, CR+3=10E2, Na+, K+, Mg+2, CA+2, Zn+2, Al+3=10E5

CD-200

Solid Membrane

Copper ion, combination
CU-2021

0.06 to 630 mg/l Cu+2

5-6 pH / 50C

Hg+2, Ag+2 must be absent, Fe+3=10E-1, Al+3=10E1, CR+3=10E2, Na+, K+, Mg+2, CA+2, Zn+2, Al+3=10E5

CU-200

Solid Membrane

Silver ion, combination
AG-2021

0.1 to 108K mg/l Ag+

5-6 pH / 50C

Hg+2 must be absent, Mg+2=10E3, CA+2, CU+2, Pb+2, Cd+2, Zn+2=10E4, Na+, K+=10E6

AG-200

Solid Membrane

Sulfide ion, combination
S-2021

0.3 - 32K mg/l S-2

>13 pH

---

S-200

Solid Membrane

Ammonium Electrode (membrane type) AE-2041

0.09 - 1800 mg/l NH4+

>12 pH / 50C

volatile amines

AE-Film

AE-2041 (Set of 10)

Carbon Dioxide (membrane type) CE-2041

Dissolved gas: 
1.49 to 1490mg/l

- / 50C

Dissolved gas: volatile weak acid 
Atmosphere: Acidic gas

CTC-211 Diaphragm cartridge

CE-2041 (set of 4)

Notes on ion electrodes:: Selective coefficient: 10Ex denoted that a concentration of interfering ion in the sample soluton, that is greater than that of measured ion will give the same meter indication. 
When coexisting ions are at a concentration that will affect the measurement value, solution pretreatment will be required to prevent or minimize interference.

The Combined ion electrodes are not designed as water proof sensors and are not built with temperature probes included.


 
Ask about this product