DC to 20 kHz/200A AC/DC Clamp On Current Probe
Hioki AC/DC clamp sensors are best-in-class current sensors for use with power meters, Memory HiCorders and high performance oscilloscopes. The CT9692 and CT9692-90 with sensor unit attachment is a DC to 20 kHz/200A sensor, ideal for capturing current signals from solar power generation systems, UPS and batteries.
• CT9692 (Clamp on AC/DC Sensor only)
• CT9692-90 (CT6590 bundled with CT9692)
Note 1: Cannot be used alone. To use the CT9692 sensor with the Hioki PW3198 Power Quality Analyzer or the Hioki Memory HiCorder series, it must be connected and powered via the Sensor Unit CT6590
Note 2: The CT9692 sensor may also be used with the Clamp On AC/DC HiTester 3290/ 3290-10 (without the Sensor Unit CT6590)
Ideal for solar power generation systems, UPS and battery testing
• Wide DC to 20 kHz bandwidth
• Applications in solar power generation, battery charge and discharge, and measuring the secondary side of inverters
• For observing waveforms in combination with oscilloscopes or Hioki Memory HiCorders (use with the CT6590)
Basic specifications (Accuracy guaranteed for 1 year, or opening and closing of the clamp sensor 10,000 times)
Rated input current | 200 A AC/DC |
---|---|
Max. allowable input | Continuous 200 Arms |
Bandwidth | DC to 20 kHz (-3dB) |
Max. rated voltage to earth | 600 V AC/DC CAT III |
Power consumption | 50 mVA |
Core diameter | φ 33 mm (1.30 in) |
Dimensions and mass | 62 mm (2.44 in) W × 167 mm (6.57 in) H × 35 mm (1.38 in) D, 410 g (14.5 oz) |
Cord length | 2 m (6.56 ft) |
Accessories | Instruction manual ×1 |
■ CT6590 basic specifications (Power supply for sensor, Accuracy guaranteed for 1 year)
Compatible sensor models | CT9692, 9692 (Discontinued model 9692: Phase not defined) |
---|---|
Output | Selectable H range/ L range, BNC terminal |
Output (in combination with a sensor) | 200 mV f.s./200 A range 200 mV f.s./20 A range |
Amplitude basic accuracy (in combination with a sensor) | ±1.5 % rdg. ±0.5 % f.s. (DC ≤ f ≤ 66 Hz) |
Phase basic accuracy (in combination with a sensor) | ±2 deg. (DC < f ≤ 66 Hz) |
Power supply | LR6 (AA) alkaline batteries ×2, Continuous use : 25 hr (Rated Power 1 VA), or AC adapter 9445-02/-03 (Rated Power 1.5 VA), or External power supply 5 to 15 V DC (Rated Power 1.5 VA) |
Dimensions and mass | 36 mm (1.42 in) W × 120 mm (4.72 in) H × 34 mm (1.34 in) D, 165 g (5.8 oz) (including batteries), cord length 1 m (3.28 ft) |
Accessories | LR6 (AA) alkaline batteries ×2, Instruction manual ×1, Connector cover ×1 |