Kyoritsu 2003A Equipped to measure both AC and DC current with transformer jaws of large diameter. • Can measure AC and DC currents up to 2000A. • Output terminal for connection to recorders. AC/DC Digital Clamp Meters
Kyoritsu 3121A/3122A/3123A Rugged design with a hard carrying case for field use   • Detachable High Voltage Line probe   • Automatic ranges, high and low scales, indicated by different LED's   • Drip proof (IP41) High Voltage Insulation Tester
Kyoritsu 8121 Applicable model 5010/5020 Conductor size Φ24 Rated current AC 100A Output voltage AC 500mV/100A (AC 5mV/A) Accuracy |±2.0%rdg±0.3mV (50/60Hz)|±3.0%rdg±0.5mV (40Hz~1kHz) Withstand voltage AC 3540V for 5 seconds Cable length Approx. 2m Output connector MINI DIN 6pin Operating temperature ranges 0~40ºC, less than 85% RH (without condensation) Output impedance Approx. 9.5Ω Applicable standards IEC 61010-1:2001,IEC... Load current clamp sensors
Kyoritsu 8035 New technology permits safe testing, without the need of direct contact between probes and live wires. • The insulated crocodile clips can clip insulated cables from φ2.4 to 30mm. • Phase rotation is indicated by the rotary illumination of LEDs and logical audible tones. • The instrument can be fixed to a metal panel via the magnet on the back side. • Wide measuring range for 3 phase installations from 70V to 1000V AC. • Super brightness function... Phase Indicator
Kyoritsu 2300R True RMS reading is an essential feature for accurate measurement. • “Non Contact” voltage function indicates the presence of AC voltage by warning the user with an audible signal. • Set the DC current range to zero in one touch with the Zero Adjust function. Fork Current Tester
Kyoritsu 8146 Applicable model 5010/5020, 6310, 6315 * Cannot be used for power measurement. Conductor size Φ24 Rated current AC 30A Output voltage AC 1500mV/30A (AC 50mV/A) Accuracy 0~15A|±1.0%rdg±0.1mV (50/60Hz)|±2.0%rdg±0.2mV (40Hz~1kHz) 15~30A|±5.0%rdg (50/60Hz)|±10.0%rdg (45Hz~1kHz) Withstand voltage AC 3540V for 5 seconds Cable length Approx. 2m Output connector MINI DIN 6pin Operating temperature ranges 0~50ºC, less than... Leakage & Load current clamp sensors
Kyoritsu 8205AMultifunction and Safety Testers demo panel This demonstrative panel is intended to demonstrate the use Multifunction testers and specific instruments like Continuity, Insulation, Earth, Loop and RCD testers of Kyoritsu. The panel simulates an electrical installation with TT and TN distribution systems, easy selectable by a switch on the panel. The tests that can be carried out are: • Continuity Test of Protective and Equipotential conductors • Insulation Resistance Test • Earth Resistance Test (Volt-Ampere... Demonstration Panels
Kyoritsu 4102A The latest circuit design permits the instrument to operate with the minimum of influence from earth voltage and earth resistance of auxiliary earth spikes. • Dust and drip proof. (designed to IEC 529 IP54) • Earth resistance value can be read directly from the scale. • Designed to meet IEC 61010-1 safety standard. • Capable of measuring earth voltage. • Small and lightweight. Shock resistant new case material. • 2mA measuring current... Earth Testers
Kyoritsu 8141 Applicable model 5000/5001, 5010/5020, 6310 * Cannot be used for power measurement. Leakage current clamp sensors
Kyoritsu 2412 Digital clamp meter with tear drop shaped, medium size transformer jaws specially designed for leakage current measurement. • Frequency filter switch to eliminate the effect of harmonics. • Output terminal for connection to recorders and facility to operate from external power supply permit continuous leakage current monitoring. Leakage Clamp Meters
Kyoritsu 4140 Anti-Trip Technology for complete trip free Loop testing on all RCDs rated 30mA and above. • Dual Display allows simultaneous measurements like Loop & PFC/PSC. • Two wire connection for Loop L-L, L-N and PSC testing is possible. • Phase rotation, Voltage and Frequency measurements. • Lock-down test button for 'hands free' testing with auto-start operation. LOOP / PFC / PSC Tester
Kyoritsu 5410 Measurement of RCD trip timeConducting testing of rated residual non-operating currents at × 1/2 Range, measuring RCD trip time at × 1 and × 5 Ranges. • Measurement of trip out currentMeasuring trip out current by varying current automatically. • Remote TestEnabling a user to hold the Test Leads with his both hands by locking the Test Button. Measurement will automatically start when the main voltage is detected. • Voltage MeasurementCarrying out a constant... RCD Tester
Kyoritsu 6016 Continuity Measurement Continuous testing can be carried out by use of the test button lockdown feature. A selectable buzzer gives instantaneous indication of continuity. Null facility eliminates the test lead resistance from the results, the nulled value is retained even if the instrument is switched off. Live circuit warnings are given by a flashing LED, buzzer and indication on the display. Insulation Measurement Three selectable test voltages 250V, 500V and 1000V.... Multi Function Testers
Kyoritsu 6050 (LOOP+RCD) Kew Combitester provides the ultimate in Microprocessor technology offering Loop and RCD tests with a comprehensive memory and downloading test results. • LOOP Impedance 200/2000Ω range measurement is carried out using a test current of 15mA. This current will not trip RCD’s rated at 30mA or greater. • High resolution for low Loop Impedance (resolution of 0.01Ω) on 20Ω range. • Direct reading of Prospective Short Circuit Current (PSC) and earth fault... Combi Tester
Kyoritsu 6201A The KEW 6201A is a portable appliance tester, performing four functions to ensure the Safety of ClassI and ClassII appliances. And also can measure the mains voltage. Readings are displayed on a large liquid crystal display (LCD) below which are four LEDs which unambiguously display a pass or fail indication for threshold values dictated by AS/NZS 3760. Portable Appliance Testers
Kyoritsu 6305 Comprehensive real-time monitoring, recording and analysis of single and 3-phase systems • Voltage, Current, Power Factor and Frequency measurements • Power analysis (Active, Apparent and Reactive power) • Energy analysis (Active, Apparent and Reactive power) • Active power accuracy: ±0.3%rdg±0.2%f.s. • Automatic wiring check function to prevent incorrect connections • Large memory capability (2GB) using built-in SD card... Power Meter
Kyoritsu 8115 Permits extension of the AC and DC current ranges of almost any Digital Multimeters (DMMs) without breaking the circuit under test. • Using KEW 8115 with KEW 1051/1052 (DMM) the display can be set for direct reading in A. Sensors, Multi-Trans, Clamp adaptors
Kyoritsu Discontinued products MODEL Descriptions Remark Alternative 1007 Digital Multimeter   1009 1008 Digital Multimeter   1009 1010 Solar Pocket Tester Solar battery No 1015 Digital Multimeter   1018 1017 Digital Multimeter   1018 1020 Digital Multimeter Automatic mode switchingbetween AC and DC voltage measurements. No 1103 Analogue Multimeter   1110 1104 Analogue Multimeter with 1000V range and10A... Discontinued products
Kyoritsu 5001 THE LEAKAGE CURRENT IS RECORDED BY 3CH INPUT60,000 DATA IS RECORDED 60,000 data is recorded when 1ch is used and when three all channels are used, 20,000 data is recorded for each channel Continuous measurement time   About 40 days   Data where it doesn’t disappear even if battery is consumed   Data doesn’t disappear by using the nonvolatile memory when the battery is consumed and the battery is exchanged.... Logger
Kyoritsu KEW MATE 2000 Capable of measuring AC and DC currents up to 60A with OPEN CLAMP SENSOR. • 3400 counts with bargraph display. • Pocket size and heavy duty design.   Digital Multimeter with AC/DC Clamp Sensor