By Brands

Brands

  • Filter
  Name SKU Description Category
AC Voltage (50Hz to 400 Hz):Trms Range Resolution Accuracy Sensitivity Overload Protection 999.99 mV 0.1mV ±1% ± 0dgts(50,60Hz) ±2%±20dgts(40~100Hz) 2.0mV 600V 9.999 V 1mV 0.020V 99.99V 10mV ±1% ± 20dgts(50,60Hz) ±2% ±20dgts(40~ 3-3/4 Digital LCD, 4000 count, Autoranging. Trms KW, Current, Voltage measurement. AC Current 0.1A to 700A. Resistance and Continuity test. Data hold & MAX function. Pocket size. Auto Power off. IEC1010-1 CAT III 600V Power Clamp Meter
AFLEX-3001/3002 Flexible AC Current Clamp True RMS 3000A Voltage Measurement (AFLEX 3002 only) Fast Peak Function(30 μs) MAX/MIN Auto-Power-Off:30 minutes Flexible probe, different from normal clamp meter, can pass through obstacles at will and wind many conducting wires simultaneously, max. diameter 170mm Flexible AC Current Clamp
AFLEX-3003 Flexible VA Harmonics Tester AFLEX -3005 Flexible Power Quality Tester Power Analysis (3005) W, KW, H.P. VA ,KVA, VAR, KVAR PF, Phase Angle( Φ ) Energy (WH, KWH) Dual displays (W+PF, VA+KVAR) Balanced 3 Φ Power Quality and Sequence Harmonics Analysis True RMS (V and A) 3000 A Non-interrupted Harmonic Analysis ( V and A ) to the 50th Order in % and Magnitude Analysis of % THD-F and C.F. Fast Peak Function (33μs and 39μs) Programmable PT (1 to 250 )ratios Auto - Power - Off : 30 Minutes Flexible AC Current Clamp
AFLEX-6300 Graphic Power Quality Analyzer Display of Overlapped Voltage and Current Waveform Maximum Demand (MD in W, KW, MW) with Programmable Period Harmonics Analysis ( V and I ) to the 50th Order Display of 25 Harmonics in One Screen with Waveform Display of waveform with Peak Values (512 Samples / Period), Datalogging of 32, 64, 128 or 256 Points/Cycles Analysis of Total Harmonics Distortion ( % THD-F ) Graphic Phasor Diagram Programmable PT (1 to 3000) Ratios Capture 128 Transient Events ( Time + Cycles + Faults )... Flexible AC Current Clamp