By Brands

HIO0219-HIOKI RM3545 RESISTANCE METER

Resistance Meter. Wide Range 10 m to 1000 M DC Resistance Meters with Multiplexer Option for High-speed Multi-point Testing.

  • 0.01 µΩ to 1.200 GΩ. RS-232C, RS-232C Printer, and USB Interfaces.
  • 0.006% basic accuracy, 0.01 μΩ max. resolution, 1A max. measurable current
  • Measure from 0.00 μΩ (testing current 1 A) to 1200 MΩ
  • Multiplexer Unit Z3003 (option) provides 20-channels of 4-terminal measurements for a complete assessment of multi-point signals (RM3545-02 only)
  • Low-power resistance measurement with an open voltage not exceeding 20 mV
  • High-speed, comprehensive productivity support delivers decisions in as little as 2.2 ms from start to finish

Hioki RM3545

  • 0.01 µΩ to 1.200 GΩ. RS-232C, RS-232C Printer, and USB Interfaces
  • 0.006% basic accuracy, 0.01 μΩ max. resolution, 1A max. measurable current
  • Measure from 0.00 μΩ (testing current 1 A) to 1200 MΩ
  • Multiplexer Unit Z3003 (option) provides 20-channels of 4-terminal measurements for a complete assessment of multi-point signals (RM3545-02 only)

Resistance Meter

Hioki DC resistance meters measure a broad range of resistance values at a high level of precision. The RM3545 is super-high-precision, multichannel-capable resistance meters that meet applications in advanced research and production for testing winding resistance of motors and transformers; contact resistance of power relays, switches, and connectors; and resistance of signal relays and magnetic parts.

Super-high-accuracy, Multi-channel Resistance Meter

For use in Advanced Development and Production Applications

Low-power (LP) resistance measurement

The RM3545 can perform measurement at a resolution of 10 μΩ at 1 mA (using the 1,000 mΩ range). With an open-terminal voltage of 20 mV or less, the instrument is ideally suited for measuring the contact resistance of chip inductors and signal contacts.

D/A output

The RM3545 converts resistance measured values into DC voltage for output. This capability is convenient when continuously recording changes in resistance, for example as detected by a sensor, with a logger or other piece of equipment.

 

High/low current selection by range

Select the optimal measurement current by switching between high and low settings according to the characteristics of the sample.

Extensive contact check functionality

The RM3545 can detect erroneous measurements caused by improper contact, reducing the risk that improperly judged or unchecked parts will be shipped by mistake. Contact check functionality is also provided for 4-terminal measurement.

In The Box

Hioki - IM3536

Manufacturer Specs

Tech Specs

 

 

Ask about this product