• Filter
  Name SKU Description Category
HOB301-UX120-017 4-CHANNEL PULSE, EVENT, STATE AND RUN-TIME DATA LOGGER (LOGGER ONLY) The HOBO UX120 Pulse Logger is a highly versatile, 4-channelenergydata logger that combines the functionality of four separate data loggers into one compact unit. It enables energy management professionals – from energy auditors to building commissioners – to easily track building energy consumption, equipment runtimes, and water and gas flow rates. The HOBO UX120 Pulse Logger is available in astandard memory model (UX120-017)capable of 500,000 measurements and anexpanded memory version... Datalogger/Recorders
HOB901/HOB902 SOFTWARE KIT FOR WINDOWS/MAC (INCLUDES SOFTWARE AND CABLE) This totally new HOBOware for Windows supports all HOBO U-Series loggers, including HOBO Water Level and HOBO Pendant loggers; Onset's HOBO Weather Station and HOBO Micro Station; and incorporates valuable new capabilities such as scaling data to sensor units and saving graphs so they can be recalled and used in the future. In addition, HOBOware Pro includes Post-Processing Assistants, for Growing Degree Days and Grains per Pound. The USB Interface cable is included with the HOBOware... Datalogger/Recorders
HOB402 U12-012 TEMP/RH/LIGHT/1 X EXTERNAL ANALOG DATA LOGGER (LOGGER ONLY) The HOBO U12 Temp/RH/Light/External is a four-channel data logger that provides temperature, relative humidity, relative indoor light level measurements and accepts one external input. >> Temperature, Humidity, Light with 1 External Analog Input for Current or DC Voltage Measurement >> 0 to 2.5 Volts DC, 0 to 5 Volts DC (w/ #CABLE-ADAP5), 0 to 10 Volts DC (w/ #CABLE-ADAP10) Measurement Ranges >> -20°C to 70°C (Temperature); 0 to 95% RH (Humidity); 1 to 3000 lumens/ft2... Datalogger/Recorders
HOB906 U-DT-1 U SHUTTLE DATA TRANSPORTER/DATA COLLECTOR The pocket-sized Shuttle provides a convenient way to readout and relaunch many of the HOBO data loggers and bring the data back to your host PC. The HOBO Shuttle works with the HOBO U-series loggers and HOBO Weather Stations and Micro Weather Stations. Features 4 MB non-volatile memory, allowing you to readout many loggers (504 loggers with 8K memory - some Pendant Loggers) (63 loggers with 64K memory - most U-Series Loggers) (7 loggers with 512K memory - weather/micro stations and... Datalogger/Recorders
HOB904 CABLE-ADAP10 0-10V INPUT CABLE 0 to 10 Volts DC External Input Cable>> Input Range: 0 to 10 Volts DC >> Impedence: 20 KΩ with 0.6 mV Resolution >> Cable: 13mm (0.5") Tinned Braided Wire Leads >> Cable Length: 1.9 Meters (6.3 feet) >> Indoor Use Only   Datalogger/Recorders
HOB903 CABLE-4-20MA 4-20MA INPUT CABLE 4-20mA Input Cable >> Cable for Connecting Sensor with 4-20mA Output to Logger >> Length: 18.5" >> Use in Outdoor and Indoor Environments Datalogger/Recorders
HOB404 U12-013 TEMP/RH/ 2 X EXTERNAL ANALOG INPUT DATA LOGGER >> Temperature, Humidity with 2 External Analog Inputs for Current or DC Voltage Measurement >> 0 to 2.5 Volts DC, 0 to 5 Volts DC (w/ #CABLE-ADAP5), 0 to 10 Volts DC (w/ #CABLE-ADAP10) Measurement Ranges >> -20°C to 70°C (Temperature); 0 to 95% RH (Humidity); 1 to 3000 lumens/ft2 (Light) Operating Ranges >> Stores up to 43,000 Measured Samples/Readings >> Sampling Rate of 1 Second to 18 Hours Adjustable by User >> 1 Year Replaceable Battery Life... Datalogger/Recorders
HOB403 U12 Outdoor/Industrial Data Logger with 4 External Channel Inputs >> Weatherproof Enclosed Logger with 4 External Inputs for Measuring and Recording Multiple Parameters >> 0 to 2.5 Volts DC, 0 to 5 Volts DC (w/ #CABLE-ADAP5), 0 to 10 Volts DC (w/ #CABLE-ADAP10) Measurement Ranges >> -20°C to 70°C (Temperature) and 0 to 95% RH (Humidity) Operating Range >> Stores up to 43,000 Measured Samples/Readings >> Sampling Rate of 1 Second to 18 Hours Adjustable by User >> 1 Year Replaceable Battery Life >> Requires HOBOWare... Datalogger/Recorders
HOB401 U12 4 CHANNEL EXTERNAL INPUT DATA LOGGER (LOGGER ONLY)   Onset HOBO Data Logger Accepts External Sensors for Temperature, AC/DC Voltage, AC Current, 4-20mA, and CO2>> 4 External Inputs for Measuring and Recording Multiple Parameters>> 0 to 2.5 Volts DC, 0 to 5 Volts DC (w/ #CABLE-ADAP5), 0 to 10 Volts DC (w/ #CABLE-ADAP10) Measurement Ranges>> -20°C to 70°C (Temperature) and 0 to 95% RH (Humidity) Operating Range>> Stores up to 43,000 Measured Samples/Readings >> Sampling Rate of 1 Second to 18... Datalogger/Recorders
HAC001B-HAND HELD MONITOR 200 FOR ALPHA, GAMMA, BETA, X-RAYS - FROM USA SE INTERNATIONAL  HAND HELD MONITOR 200 FOR ALPHA, GAMMA, BETA, X-RAYS NEW     The Monitor 200 measures alpha, beta, gamma, and x-rays. Its digital display shows readings in your choice of CPM, CPS, μSv/hr, mR/hr, or in accumulated counts. It has a digital display, a red count light, and a beeper that sounds with each count detected. Other features include an adjustable timer, and selectable alert. With the free Observer USB Software Family, you can set computer alarms, and download your... Nuclear Radiation Monitor
HAC002B-Ionizing Radiation Detector with External Detector(Geiger Counter)-Alpha, Gamma,Beta Rays Counter Four-digit, LCD display External probe detects low levels of alpha and beta particles, gamma and x-rays for a range of ionizing radiation type detection Red count light and beeper indicate each ionizing radiation change event Comes with a carrying case that provides open access to the display window and operation panel, and has a probe cover that protects the detector, and allows for one-handed operation 1 year limited warranty Nuclear Radiation Monitor
HAC002-INSPECTOR(VERSION 2) ALERT RADIATION MONITOR WITH XL SENSOR AREA(FROM USA) Product Description Quickly alerts the user to the presence of harmful levels of nuclear radiation Improves safety in the laboratory and in the field Automatically compensates for GM tube dead time Will not jam in high radiation fields CE Certified, RoHS Compliant & Meets WEEE standards   Nuclear Radiation Monitor
HAC001S1 USB PC SOFTWARE GEIGER GRAPH FOR RADLERT/CRM/INSPECTOR GEIGER COUNTER - FROM USA You can configure the program so that a Radiation Alert executes a computer program or batch file, and/or sets voltage to another serial port on the computer to trigger a relay switch that stops a machine, for instance.  Pleasing interface, including and easy to understand running total and summary of Radiation Count data,  attractive 3D graphing, a flashing LED with each radiation count, and handy speed buttons. Identify your monitoring station and... Nuclear Radiation Monitor
HAC001E-CRM-100V2 BASIC RADIATION MSV/HR MREM/HR METER(HANDHELD NUCLEAR RADIATION METER) - FROM USA *Without Auto Alert Function.The CRM-100™ is a general purpose geiger counter that measures alpha, beta, gamma, and x-radiation. It is intended for personal safety and educational purposes. Like the popular Radalert 100™, the CRM-100™ features a 3-second update on its digital liquid crystal display (LCD). The LCD shows the current radiation level in your choice of milliroentgens per hour from .001 to 110 or counts per minute (cpm) from 0 to 350,000. When SI units are selected, the LCD... Nuclear Radiation Monitor
HAC001-RADALERT 100V2 RADIATION MSV/HR MREM/HR METER(HANDHELD NUCLEAR RADIATION MONITOR) - FROM USA The Radalert HAC001 is a general purpose geiger counter that measures alpha, beta, gamma, and X-radiation. Exciting new features of the Radalert 100™ (which is the upgraded version of the popular Radalert 50™), include a three-second update and a utility menu that allows you to change the default settings for several operating parameters. Its digital liquid crystal display (LCD) shows the current radiation level in your choice of milliroentgens per hour from .001 to 110 or counts per minute... Nuclear Radiation Monitor
HIO0195-HIOKI ST5520 INSULATION TESTER ST5520 Insulation Testers (with External I/O Output) Rapidly assess in as fast as 50 ms Quick discharge of residual voltage Freely configurable test voltage (Set from 25 V to 1000 V, 1 V resolution) Contact check function (Prevents errors due to poor contact) Short-circuit check function (Stops potentional defects from reaching the market) Insulation Testers The Hioki electrical safety test instrument series is designed for insulation resistance and voltage withstand testing of... Insulation (Resistance) testers
HOB510C-M002V2 RAIN GAUGE SMART SENSOR (0.2MM) WITH 2M CABLE COMPLETE W USB SOFTWARE AND LOGGER This Rain Gauge Smart Sensor measures rainfall with intensity up to 12.7 cm per hour with a resolution of 20 mm, and 1% accuracy for rainfall rates up to 0.2 mm/hour. The tipping bucket mechanism is mounted on a stainless steel shaft with brass bearings. This model includes a 2m cable. Environment:The S-RGB-M002 Sensor is for use in Outdoor environments Measurements:The S-RGB-M002 Sensor supports the following measurements: Rainfall Rain gauge
HIO0320-HIOKI L2104 4 -TERMINAL LEAD 4 -Terminal Lead B: 118 mm (4.65 in), L: 1.5 m (4.92 ft) Test-leads
HIO0213-HIOKI 9780 BATTERY PACK The Hioki 9780 NiMH Battery Pack is charges while installed in the main unit. It is designed for use with MR8870 Memory Recorders, LR8431 Data Loggers, and 8430-20 Memory HiLoggers. NiMH battery pack 3 VA, continuous operating time of approx. 2 hr. Charging time of 200 min. For use with 8870 Memory HiCorders and LR8431 Memory HiLoggers Battery and Chargers