Hioki 3153
- 3153 Automatic Insulation/Withstanding Tester
- Programable testing, full remote control, Automatic Insulation Withstanding Tester
- Insulation and AC/DC continuous voltage withstand testing
- Safety standards compliance testing
Automatic Insulation/Withstanding Tester.
This electrical safety test instrument series is designed for insulation resistance and voltage withstand testing of electrical devices and components according to various safety standards. A multitude of automation and labor-saving features are provided to ensure effective testing for a wide variety of requirements and test conditions. Select the most appropriate model for your applications.
In The Box
- 9615 H.V. TEST LEAD (high voltage side and return, 1 each)
- Power cord (1)
- spare fuse (1)
Manuals/Guides
Manuals
- Hioki Insulation Voltage Withstand Test Instrument Series User Guide
- User Manual
- Hioki Insulation Voltage Withstand Test Instrument Series Data Sheet
Manufacturer Specs
| Hioki Insulation Voltage Withstand Test Instrument Series Specifications | |||||||||||||
| Voltage Withstand Testing | |||||||||||||
| Model 3153 AUTOMATIC INSULATION / WITHSTANDING HiTESTER |
Model 3159 INSULATION / WITHSTANDING HiTESTER |
Model 3158 AC WITHSTANDING VOLTAGE HiTESTER |
|||||||||||
| AC | DC | AC | |||||||||||
| Output voltage | 0.20 to 5.00 kV | 0.20 to 5.00 kV | Two ranges: AC 0 to 2.5 or 5.0 kV | ||||||||||
| Voltage output method |
PWM switching method (zero-switching) |
PWM switching method | Zero-switching | ||||||||||
| Transformer capacity | 500 VA (rated 30 minutes) | ... | 500 VA (rated 30 minutes) | ||||||||||
| Output capacity | ... | 50 VA (continuous) | ... | ||||||||||
| Voltage adjustment method |
Digital setting (0.01 kV setting resolution) | Manual adjustment | |||||||||||
| Voltage change rate | ±7% or less (max. 5 kV at 100 mA → unloaded: with resistive load)*2 |
±16% or less (max. 5 kV at10 mA → unloaded: with resistive load)*2 |
... | ||||||||||
| Voltage waveform | Sine wave (5% or less distortion, unloaded) |
... | Power waveform | ||||||||||
| Voltage frequency | 50 or 60 Hz ±0.2% | ... | Power synchronization | ||||||||||
| Output ripple voltage | ... | 6% of output voltage or less (at 5 kV DC, 10 mA, resistive load) |
... | ||||||||||
| Output current | 100 mA *1 | 10 mA (continuous) | ... | ||||||||||
| Voltmeter | Average rectified effective value display | Average display | Average rectified effective value display Digital: 0.00 to 5.00 kV (full scale) Accuracy: ±1.5% f.s. Analog: 0 to 5 kV (full scale) Accuracy: ±5% f.s.a |
||||||||||
| Digital: 0.00 to 5.00 kV (full scale) Accuracy: ±1.5% f.s. Analog: 0 to 5 kV (full scale) Accuracy: ±5% f.s. |
|||||||||||||
| Current measurement range |
0.01 to 100.0 mA | 0.01 to 10.0 mA | 0.01 to 120.0 mA | ||||||||||
| Indicated value range | 10 or 100 mA | 10 mA | 2, 8, 32 or 120 mA | ||||||||||
| Measurement resolution |
0.00 to 10.00 or 0.01 mA (10-mA range) 10.1 to 100.0 or 0.1 mA (100-mA range, AC only) |
0.01 mA (2- or 8-mA range), 0.1 mA (32-mA range), 1 mA (120-mA range) |
|||||||||||
| Current measurement accuracy |
± (2% rdg. + 5 dgt.) common to each range *3 | ± (3% f.s. + 20 µ A) for all ranges (at 5% power distortion or less) | |||||||||||
*1. Time vs. Output Voltage (at 23˚C ambient)
*2. Unloaded = 40 M Ω load (instrument input impedance) *3. Plus scanner accuracy, when used. |
|||||||||||||
| Insulation Resistance Testing | |||||||||||||
| Model 3153 | Model 3159 | Model 3158 | |||||||||||
| Test voltage | Output voltage: Positive polarity 50 to 1200V DC Voltage adjustment method: Digital setting (1V resolution) Output voltage accuracy: ±1.5% ±2 dgt. of setting level |
Rated voltage: 500 or 1000V DC Unloaded voltage: 1 to 1.2 times rated voltage |
... | ||||||||||
| Rated measurement current |
1 mA | 1 to 1.2 mA | ... | ||||||||||
| Short-circuit current | 200 mA or less | 4 to 5 mA (500V) 2 to 3 mA (1000V) |
... | ||||||||||
| Voltmeter | Average display Digital: 0 to 1200V DC (full scale) Accuracy: ±1.5% rdg. ±2 dgt. Analog: 0 to 1200V DC Accuracy: ±5% f.s. (5 kV full scale) |
Average display Digital: 0 to 1200V DC (f.s.) |
... | ||||||||||
| Analog: not applicable | |||||||||||||
| Measurement range/ accuracy |
0.100 to 1.049 M Ω 1.05 to 10.49 M Ω *1 10.5 to 104.9 M Ω *1 105 to 9999 M Ω *1 Fundamental accuracy: ±4% rdg.*2 |
0.5 to 999 M Ω (500V)/±4% rdg. 1 to 999 M Ω (1000V)/±4% rdg. 1000 to 2000 M Ω /±8% rdg. |
... | ||||||||||
| *1. Measurement range changes according to test voltage. *2. Plus scanner accuracy, when used. |
|||||||||||||
| Decision Function | |||||||||||||
| Model 3153 | Model 3159 | Model 3158 | |||||||||||
| Decision method | Window comparison method (digital specification) | ||||||||||||
| Decision results | UPPER-FAIL: Measured current (insulation resistance value) exceeded the specified upper bound. PASS: Measured current (insulation resistance value) was between the specified upper and lower bounds during the specified time elapsed LOWER-FAIL: Measured current (insulation resistance value) was less than the specified lower bound (Note: Model 3158 has no insulation resistance function) |
||||||||||||
| Decision processing | For each decision result, output the display portion, the beeper sound, and EXT I/O signal | ||||||||||||
| Specification ranges | Voltage withstand testing: ACV: 0.1 to 100 mA (upper bound) / 0.1 to 99 mA (lower bound) DCV: 0.1 to 10 mA (upper bound) / 0.1 to 9.9 mA (lower bound) Insulation testing: 0.10 to 9999 M Ω (same upper/lower bounds) |
Voltage withstand testing: 0.1 to 120 mA (upper bound) / 0.1 to 119 mA (lower bound) Insulation testing (Model 3159 only): 0.2 to 2000 M Ω (same upper/lower bounds) |
|||||||||||
| Specification resolution |
Voltage withstand testing: 0.1 mA (0.1 to 9.9 mA), 1 mA (10 to 100 mA) Insulation testing: 0.01 M Ω (0.10 to 9.99 M Ω ), 0.1 M Ω (10.0 to 99.9 M Ω ), 1 M Ω (100 to 9999 M Ω ) |
Voltage withstand testing: 0.1 mA (0.1 to 9.9 mA), 1 mA (10 to 120 mA) Insulation testing (Model 3159 only): 0.01 M Ω (0.2 to 2 M Ω ), 0.1 M Ω (2.1 to 20 M Ω ), 1 M Ω (21 to 200 M Ω ), 10 M Ω (210 to 2000 M Ω ) |
|||||||||||
| Timers | |||||||||||||
| Model 3153 | Model 3159 | Model 3158 | |||||||||||
| Testing timer | Specification range: 0.3 to 999 s Specification resolution: 0.1 s (0.3 to 99.9 s), 1 s (100 to 999 s) Accuracy: ±0.5% of specified value |
Specification range: 0.5 to 999 s Specification resolution/accuracy: 0.1 s (0.5 to 99.9 s), ±50 ms; 1 s (100 to 999 s) ±0.5 s |
|||||||||||
| Action: (when ON is specificed) after starting, the countdown from the specified time is displayed. (when OFF is specified) displays the elapsed time from starting |
|||||||||||||
| Ramp timer (withstand test time) |
Specification range: 0.1 to 99.9 s ramp-up and -down specified separately Specification resolution/accuracy: 0.1 s, ±0.5% of specified value |
... | |||||||||||
| Delay timer (insulation resistance test time) |
Specification range: 0.1 to 99.9 s Specification resolution/accuracy: 0.1 s, ±0.5% of specified value Action: specify a delay time after testing is set to begin to inhibit decisions during that time |
Non-deterministic interval: 0.5 s (Mask time until determination begins during insulation resistance testing) |
... | ||||||||||
| Interfaces | |||||||||||||
| Model 3153 | Model 3159 | Model 3158 | |||||||||||
| EXT I/O | Open-collector outputs, active low, max. 30V DC loaded voltage, all signal lines photocoupler-isolated | ||||||||||||
| EXT SW | START, STOP, SW.EN (panel terminal switch enabled), connection point inputs | ||||||||||||
| RS-232C | Start-stop synchronization, full duplex, 9600 or 19200 bps | Start-stop synchronization, full duplex, 9600 bps | |||||||||||
| GP-IB | IEEE 488.2 (1987) compliant | ... | |||||||||||
| General Specifications | |||||||||||||
| Model 3153 | Model 3159 | Model 3158 | |||||||||||
| Display | Fluorescent display tube (digital display), analog meter | ||||||||||||
| Monitor functions | Output voltage, detected current, measured resistance | Output voltage, detected current | |||||||||||
| Monitor period | 2 times per second minimum | ||||||||||||
| Operating temperature range | 0 to 40 ˚C, 80% RH maximum (non-condensating) | ||||||||||||
| Storage temperature range | -10 to 50 ˚C, 90% RH maximum (non-condensating) | ||||||||||||
| Temperature and humidity range for guaranteed accuracy |
23 ± 5 ˚C, 80% RH maximum (non-condensating) (after 10-min. warm-up for 3153, or 5-min. warm-up for 3158 and 3159) | ||||||||||||
| Operating environment | Indoors, up to 2000m ASL | ||||||||||||
| Power supply voltage | 100 to 240V AC (installed fuse depends on actual voltage, so specify supply voltage when ordering) 100 to 120V AC: installed fuse 250V T10AL 200 to 240V AC: installed fuse 250V T5AL |
100V AC ( 3159 )...for Japan only 220V AC ( 3159-02 ) 120V AC ( 3159-01 ) 230V AC ( 3159-03 ) 240V AC ( 3159-04 ) |
100V AC ( 3158 )...for Japan only 120V AC ( 3158-01 ) 220V AC ( 3158-03 ) 230V AC ( 3158-04 ) 240V AC ( 3158-05 ) |
||||||||||
| Power supply frequency | 50 or 60 Hz | ||||||||||||
| Max. power consumption | 1000 VA | 800 VA | |||||||||||
| Dimensions | Approx. 320 (W) × 155 (H) × 480 (D) mm | Approx. 320 (W) × 155 (H) × 330 (D) mm | Approx. 320 (W) × 155 (H) × 263 (D) mm | ||||||||||
| Mass | Approx. 18 kg | Approx. 18 kg ( 3159 ), 20.5 kg ( 3159-01 ), 21.5 kg ( 3159-02/-03/-04 ) |
Approx. 16 kg ( 3158-01 ), 18 kg ( 3158-03/-04/-05 ) |
||||||||||
| Supplied accessories | 9615 H.V. TEST LEADS (high voltage side and return, one each), POWER CORD, EXTRA FUSE | ||||||||||||
| Options | 9613 REMOTE CONTROL BOX (SINGLE), 9614 REMOTE CONTROL BOX (DUAL), 9637 RS-232C CABLE (9-pin Dsub to 9-pin Dsub), 9638 RS-232C CABLE (9-pin Dsub to 25-pin Dsub), 9267 SAFETY TEST DATA MANAGEMENT SOFTWARE |
||||||||||||
| 3930 HIGH VOLTAGE SCANNER 9151-02 GP-IB CONNECTOR CABLE (2m) 9151-04 GP-IB CONNECTOR CABLE (4m) |
9616 WARNING LAMP | ||||||||||||
Tech Specs
Micro / Milli / Meg Ohmmeters/Megohmmeter / Insulation Resistance Testers Template |
|
|---|---|
| IR Test Voltage | 1,000 V, 10 V, 100 V, 2,000 V, 2,500 V, 25V, 400V, 5,000 V |
| Maximum Insulation Resistance | 9999 M Ohms (10.00 G Ohms) |
Safety Testing / Surge Testing/Hipot Tester Template |
|
| Test Type Hipot | AC, DC, IR |
| Max AC Test Voltage | 5 kV |
| Max DC Test Voltage | 5 kV |
| Min AC Test Voltage | 0.2 V |
| Min DC Test Voltage | 0.2 V |
| Max Trip Current AC Test | 100 mA |
| Programmable (hipot) | Yes |
| Insulation Resistance Test | Yes |
| Connection Type | Probe |
| Scanning control capable for Multipoint Testing | Yes |
Test Equipment General Attributes |
|
| Interfaces I/O | GPIB, RS-232 |
| Product Weight | 18 KILOS (39.68 LBS) |
| Product Height | 155 MM (6.10 IN) |
| Product Length | 320 MM (12.60 IN) |
| Product Width | 480 MM (18.90 IN) |
| ECCN Number | 3A992 |
| Power Supply Voltage | 120V/220V Universal |
| Country of Origin | Japan |
| Shipping Height | 10.50 IN |
| Shipping Length | 26.26 IN |
| Shipping Width | 18.60 IN |